| 23816 | Tamarack IEC 61850 服务器检测 | Nessus | SCADA | 2006/12/11 | 2025/7/14 | info |
| 24872 | takebishi Electric DeviceXPlorer OPC 服务器 多个漏洞 | Nessus | SCADA | 2007/3/23 | 2025/7/14 | high |
| 50687 | RealWin < 2.1.10 多种数据包类型处理溢出 | Nessus | SCADA | 2010/11/23 | 2025/7/14 | critical |
| 52962 | IGSS 数据服务器目录遍历任意文件访问 | Nessus | SCADA | 2011/3/24 | 2025/9/29 | medium |
| 52994 | Movicon TcpUploadServer 检测 | Nessus | SCADA | 2011/3/25 | 2025/9/29 | info |
| 54291 | 7-Technologies IGSS < 9.0.0.11129 多种 DoS 漏洞 | Nessus | SCADA | 2011/5/16 | 2025/7/14 | medium |
| 54645 | 7-Technologies IGSS < 9.0.0.11143 ODBC 远程内存损坏 | Nessus | SCADA | 2011/5/25 | 2025/7/14 | critical |
| 58953 | Microsys PROMOTIC < 8.1.5 多种漏洞 | Nessus | SCADA | 2012/5/1 | 2025/7/14 | high |
| 59249 | 7-Technologies IGSS < 9.0.0.11291 DLL 加载任意代码执行 | Nessus | SCADA | 2012/5/23 | 2025/7/14 | high |
| 59559 | Measuresoft ScadaPro 路径 Subversion 任意 DLL 注入代码执行 | Nessus | SCADA | 2012/6/18 | 2025/7/14 | high |
| 63430 | Siemens Automation License Manager CVE-2012-4691 拒绝服务 | Nessus | SCADA | 2013/1/9 | 2025/7/14 | low |
| 65193 | CoDeSys Gateway 服务检测 | Nessus | SCADA | 2013/3/11 | 2025/9/29 | info |
| 66805 | CoDeSys Gateway Service < 2.3.9.28 释放后使用 | Nessus | SCADA | 2013/6/5 | 2025/7/14 | critical |
| 70530 | Siemens SCALANCE X-200 认证绕过 | Nessus | SCADA | 2013/10/21 | 2025/7/14 | critical |
| 70557 | Cogent DataHub < 7.3.0 多种漏洞 | Nessus | SCADA | 2013/10/22 | 2025/7/14 | high |
| 72107 | Ecava IntegraXor < 4.1.4369 项目目录信息泄露 | Nessus | SCADA | 2014/1/23 | 2025/7/14 | medium |
| 77374 | Honeywell Excel (XL) Web 控制器检测 | Nessus | SCADA | 2014/8/25 | 2025/7/14 | info |
| 81545 | Siemens SIMATIC STEP 7 (TIA Portal) < 1300.100.2501.1 多种漏洞 (SSA-315836) | Nessus | SCADA | 2015/2/26 | 2025/9/29 | medium |
| 82269 | Honeywell XL Web 控制器 FTP 目录遍历 | Nessus | SCADA | 2015/3/26 | 2025/7/14 | critical |
| 82853 | Siemens SIMATIC WinCC (TIA Portal) < 1300.102.401.5 多种漏洞 (SSA-487246) | Nessus | SCADA | 2015/4/17 | 2025/9/29 | high |
| 83523 | Rockwell Automation RSLinx Classic < 3.73.00 缓冲区溢出 | Nessus | SCADA | 2015/5/18 | 2025/9/29 | critical |
| 87208 | 7-Technologies / Schneider-Electric IGSS 数据收集器检测 | Nessus | SCADA | 2015/12/4 | 2025/9/29 | info |
| 89029 | 7-Technologies / Schneider-Electric IGSS ODBC 服务检测 | Nessus | SCADA | 2016/2/29 | 2025/9/29 | info |
| 91623 | Cogent DataHub < 6.4.5Beta OPC 连接失败 DoS | Nessus | SCADA | 2016/6/15 | 2025/7/14 | medium |
| 151190 | Johnson Controls exacqVision Web Service 检测 | Nessus | SCADA | 2021/6/30 | 2026/3/23 | info |
| 23820 | Modicon PLC 嵌入式 HTTP 服务器检测 | Nessus | SCADA | 2006/12/11 | 2026/3/23 | medium |
| 23822 | Modicon Quantum HTTP 服务器默认凭据 | Nessus | SCADA | 2006/12/11 | 2026/3/23 | high |
| 67143 | Tridium Niagara AX Web Server 目录遍历“config.bog”泄露远程危害 | Nessus | SCADA | 2013/7/3 | 2026/3/23 | high |
| 80359 | StruxureWare SCADA Expert ClearSCADA 远程安全绕过 | Nessus | SCADA | 2015/1/5 | 2026/3/23 | medium |
| 88414 | iniNet SpiderControl PLC Editor Simatic 6.30.04 本地权限升级 | Nessus | SCADA | 2016/1/27 | 2026/3/23 | high |
| 88416 | iniNet SpiderControl SCADA Web Server 2.02 本地权限升级 | Nessus | SCADA | 2016/1/27 | 2026/3/23 | high |
| 90599 | Rockwell Automation MicroLogix 1400 PLC 默认凭据 | Nessus | SCADA | 2016/4/20 | 2026/3/23 | critical |
| 96875 | Advantech WebAccess 身份验证绕过 | Nessus | SCADA | 2017/1/30 | 2026/3/23 | critical |
| 125312 | Rockwell Automation MicroLogix 1100/1400 和 CompactLogix 5370 控制器开放重定向漏洞 | Nessus | SCADA | 2019/5/21 | 2026/3/23 | medium |
| 64487 | RuggedCom RuggedOS < 3.12.1 Web UI 多种安全漏洞 | Nessus | SCADA | 2013/2/6 | 2026/3/23 | critical |
| 73642 | Advantech WebAccess 存储的跨站脚本 | Nessus | SCADA | 2014/4/14 | 2026/3/23 | low |
| 85543 | Advantech WebAccess < 7.0-2011.08.27 多种 ActiveX RCE | Nessus | SCADA | 2015/8/19 | 2026/3/23 | medium |
| 87125 | Emerson SM-Ethernet Web 界面默认凭据 | Nessus | SCADA | 2015/12/1 | 2026/3/23 | high |
| 23823 | Modicon PLC CPU 类型 SNMP 请求型号类型远程泄露 | Nessus | SCADA | 2006/12/11 | 2026/4/8 | medium |
| 23828 | OPC 应用程序组件检测 | Nessus | SCADA | 2006/12/11 | 2026/4/8 | info |
| 51360 | Ecava IntegraXor ActiveX 的保存方法有缓冲区溢出 | Nessus | SCADA | 2010/12/22 | 2026/4/8 | high |
| 52992 | Movicon SCADA/HMI 软件检测 | Nessus | SCADA | 2011/3/25 | 2026/4/8 | info |
| 53223 | RealFlex Technologies RealWin 检测 | Nessus | SCADA | 2011/3/30 | 2026/4/8 | info |
| 58796 | Microsys PROMOTIC 检测 | Nessus | SCADA | 2012/4/19 | 2026/4/8 | info |
| 59501 | WellinTech KingSCADA 检测 | Nessus | SCADA | 2012/6/14 | 2026/4/8 | info |
| 62964 | IOServer 检测 | Nessus | SCADA | 2012/11/19 | 2026/4/8 | info |
| 70415 | ProSoft RadioLinx ControlScape 安装检测 | Nessus | SCADA | 2013/10/14 | 2026/4/8 | info |
| 43614 | Netbiter Config NetbiterConfig.exe 设备主机名远程溢出 | Nessus | SCADA | 2009/12/30 | 2026/4/8 | high |
| 109145 | Schneider Electric InTouch Machine Edition 检测 | Nessus | SCADA | 2018/4/18 | 2026/4/8 | info |
| 23824 | Modicon PLC IO 扫描状态 SNMP 请求扫描状态远程泄露 | Nessus | SCADA | 2006/12/11 | 2026/4/8 | medium |