| 149972 | Schneider Electric C-Gate 检测 | Nessus | SCADA | 2021/5/26 | 2025/7/14 | info |
| 91283 | Moxa NPort Serial-to-Ethernet 服务器检测 | Nessus | SCADA | 2016/5/20 | 2025/7/14 | info |
| 54645 | 7-Technologies IGSS < 9.0.0.11143 ODBC 远程内存损坏 | Nessus | SCADA | 2011/5/25 | 2025/7/14 | critical |
| 70557 | Cogent DataHub < 7.3.0 多种漏洞 | Nessus | SCADA | 2013/10/22 | 2025/7/14 | high |
| 53543 | RealWin < 2.1.12 多种缓冲区溢出 | Nessus | SCADA | 2011/4/25 | 2025/7/14 | critical |
| 81049 | StruxureWare SCADA Expert ClearSCADA 弱哈希算法 | Nessus | SCADA | 2015/1/28 | 2025/7/14 | medium |
| 55026 | Ecava IntegraXor 路径 Subversion 任意 DLL 注入代码执行 | Nessus | SCADA | 2011/6/9 | 2025/7/14 | high |
| 59325 | Ecava IntegraXor igcom.dll 遍历任意文件覆盖 | Nessus | SCADA | 2012/6/1 | 2025/7/14 | high |
| 63430 | Siemens Automation License Manager CVE-2012-4691 拒绝服务 | Nessus | SCADA | 2013/1/9 | 2025/7/14 | low |
| 66805 | CoDeSys Gateway Service < 2.3.9.28 释放后使用 | Nessus | SCADA | 2013/6/5 | 2025/7/14 | critical |
| 65195 | CoDeSys Gateway Service < 2.3.9.27 多种漏洞 | Nessus | SCADA | 2013/3/11 | 2025/7/14 | critical |
| 82269 | Honeywell XL Web 控制器 FTP 目录遍历 | Nessus | SCADA | 2015/3/26 | 2025/7/14 | critical |
| 149522 | PTC OPC UA 服务器多个漏洞 | Nessus | SCADA | 2021/5/17 | 2025/9/29 | critical |
| 149523 | OPC UA opc.tcp 检测 | Nessus | SCADA | 2021/5/17 | 2025/9/29 | info |
| 50303 | Moxa Device Manager 网关检测 | Nessus | SCADA | 2010/10/22 | 2025/9/29 | info |
| 97436 | Modicon Modbus/TCP UnityPro 编程功能代码访问 | Nessus | SCADA | 2017/2/28 | 2025/9/29 | medium |
| 100299 | Siemens SIMATIC WinCC (TIA Portal) 13 < 13 SP2 / 14 < 14 SP1 多个 DoS | Nessus | SCADA | 2017/5/19 | 2025/9/29 | medium |
| 102991 | Siemens SIMATIC WinCC (TIA Portal) < 14 SP1 XXE 漏洞 | Nessus | SCADA | 2017/9/7 | 2025/9/29 | high |
| 111466 | AVEVA InduSoft Web Studio / InTouch Machine Edition 命令 81 mbstowcs() 中存在堆栈溢出 | Nessus | SCADA | 2018/7/31 | 2025/9/29 | critical |
| 81578 | Siemens SIMATIC WinCC (TIA Portal) < 1300.100.2201.15 多种漏洞 (SSA-543623) | Nessus | SCADA | 2015/3/1 | 2025/9/29 | high |
| 23808 | DNP3 链路层暴力破解寻址泄露 | Nessus | SCADA | 2006/12/11 | 2025/9/29 | medium |
| 82698 | Ecava IntegraXor < 4.2.4488 权限升级 | Nessus | SCADA | 2015/4/10 | 2025/9/29 | medium |
| 86572 | 3S CODESYS Runtime Toolkit < 2.4.7.48 PLCWinNT DoS(凭据检查) | Nessus | SCADA | 2015/10/23 | 2025/9/29 | medium |
| 86573 | 3S CODESYS Runtime Toolkit < 2.4.7.48 PLCWinNT DoS | Nessus | SCADA | 2015/10/23 | 2025/9/29 | medium |
| 23823 | Modicon PLC CPU 类型 SNMP 请求型号类型远程泄露 | Nessus | SCADA | 2006/12/11 | 2025/9/29 | medium |
| 83301 | Modbus/TCP 设备标识 | Nessus | SCADA | 2015/5/10 | 2025/9/29 | medium |
| 117671 | Rockwell Automation RSLinx Classic <= 4.00.01 多个漏洞 | Nessus | SCADA | 2018/9/24 | 2025/10/7 | critical |
| 109280 | Schneider Electric InduSoft Web Studio / InTouch Machine Edition Opcode 50 mbstowcs() 中存在堆栈溢出 | Nessus | SCADA | 2018/4/23 | 2025/9/29 | critical |
| 119147 | Modicon Quantum HTTP 服务器 'formTest' 'name' 参数 XSS | Nessus | SCADA | 2018/11/26 | 2025/11/3 | medium |
| 23803 | National Instruments Lookout 检测 | Nessus | SCADA | 2006/12/11 | 2025/11/3 | info |
| 151190 | Johnson Controls exacqVision Web Service 检测 | Nessus | SCADA | 2021/6/30 | 2025/11/3 | info |
| 53877 | Samsung Data Management Server < 1.4.3 verifyUser 方法 SQL 注入 | Nessus | SCADA | 2011/5/11 | 2025/11/3 | high |
| 65602 | Schneider Electric Accutech Manager 检测 | Nessus | SCADA | 2013/3/18 | 2025/11/3 | info |
| 70292 | WellinTech KingView ActiveX 多种任意文件覆盖漏洞 | Nessus | SCADA | 2013/10/3 | 2025/11/3 | medium |
| 73645 | Advantech WebAccess Web 管理界面检测 | Nessus | SCADA | 2014/4/14 | 2025/11/3 | info |
| 83774 | WellinTech KingSCADA < 3.1.2.13-EN“kxClientDownload.ocx”ActiveX RCE | Nessus | SCADA | 2015/6/1 | 2025/11/3 | high |
| 85691 | Advantech WebAccess < 7.0-2009.06.29 多种漏洞 | Nessus | SCADA | 2015/8/28 | 2025/11/3 | critical |
| 91385 | MicroLogix 1400 PLC Web 服务器请求处理 RCE | Nessus | SCADA | 2016/5/31 | 2025/11/3 | critical |
| 95713 | 已安装 Siemens SINEMA Server | Nessus | SCADA | 2016/12/12 | 2025/11/3 | info |
| 84498 | Siemens SIMATIC ProSave 检测 | Nessus | SCADA | 2015/7/2 | 2025/11/3 | info |
| 52992 | Movicon SCADA/HMI 软件检测 | Nessus | SCADA | 2011/3/25 | 2025/11/3 | info |
| 83952 | Inductive Automation Ignition 中存在多个漏洞 | Nessus | SCADA | 2015/6/2 | 2025/11/3 | medium |
| 23807 | Siemens-Telegr ICCP 网关检测 | Nessus | SCADA | 2006/12/11 | 2025/11/3 | info |
| 84567 | Rockwell Automation MicroLogix 1100 PLC < 系列 B FRN 13.0 多种漏洞 | Nessus | SCADA | 2015/7/7 | 2025/11/3 | critical |
| 56994 | Advantech / BroadWin WebAccess webvrpcs.exe 服务远程代码执行(凭据检查) | Nessus | SCADA | 2011/12/2 | 2025/11/3 | critical |
| 131401 | Siemens SINEMA 远程连接服务器检测 | Nessus | SCADA | 2019/12/2 | 2025/11/3 | info |
| 83264 | Siemens SCALANCE S612 Firewall 检测 | Nessus | SCADA | 2015/5/6 | 2025/11/3 | info |
| 85600 | Advantech WebAccess 7.2 < 7.2-2014.07.30 多个 ActiveX RCE | Nessus | SCADA | 2015/8/24 | 2025/11/3 | medium |
| 85543 | Advantech WebAccess < 7.0-2011.08.27 多种 ActiveX RCE | Nessus | SCADA | 2015/8/19 | 2025/11/3 | medium |
| 88413 | iniNet SpiderControl PLC Editor Beckhoff 6.30.04 本地权限升级 | Nessus | SCADA | 2016/1/27 | 2025/11/3 | high |