ID名称产品系列发布时间最近更新时间严重程度
62964IOServer 检测NessusSCADA2012/11/192026/9/10
info
64487RuggedCom RuggedOS < 3.12.1 Web UI 多种安全漏洞NessusSCADA2013/2/62026/9/10
critical
70415ProSoft RadioLinx ControlScape 安装检测NessusSCADA2013/10/142026/9/10
info
81545Siemens SIMATIC STEP 7 (TIA Portal) < 1300.100.2501.1 多种漏洞 (SSA-315836)NessusSCADA2015/2/262026/9/10
medium
83523Rockwell Automation RSLinx Classic < 3.73.00 缓冲区溢出NessusSCADA2015/5/182026/9/10
critical
1271393S CODESYS V3 CmpUserMgr 3.x < 3.5.16.0 密码传输漏洞NessusSCADA2019/8/122026/9/10
high
151190Johnson Controls exacqVision Web Service 检测NessusSCADA2021/6/302026/9/10
info
23828OPC 应用程序组件检测NessusSCADA2006/12/112026/9/10
info
43614Netbiter Config NetbiterConfig.exe 设备主机名远程溢出NessusSCADA2009/12/302026/9/10
high
47759Siemens SIMATIC WinCC 默认密码认证绕过NessusSCADA2010/7/162026/9/10
high
72707Mitsubishi Electric Automation MC-WorX 套件检测NessusSCADA2014/2/252026/9/10
info
73642Advantech WebAccess 存储的跨站脚本NessusSCADA2014/4/142026/9/10
low
85543Advantech WebAccess < 7.0-2011.08.27 多种 ActiveX RCENessusSCADA2015/8/192026/9/10
medium
87125Emerson SM-Ethernet Web 界面默认凭据NessusSCADA2015/12/12026/9/10
high
88414iniNet SpiderControl PLC Editor Simatic 6.30.04 本地权限升级NessusSCADA2016/1/272026/9/10
high
95713已安装 Siemens SINEMA ServerNessusSCADA2016/12/122026/9/10
info
95714Siemens SINEMA Server < 13 SP2 无引号服务路径本地权限提升 (SSA-701708)NessusSCADA2016/12/122026/9/10
medium
96875Advantech WebAccess 身份验证绕过NessusSCADA2017/1/302026/9/10
critical
109145Schneider Electric InTouch Machine Edition 检测NessusSCADA2018/4/182026/9/10
info
1317043S CODESYS CmpWebServerHandlerV3 基于堆的缓冲区溢出NessusSCADA2019/12/42026/9/10
critical
51360Ecava IntegraXor ActiveX 的保存方法有缓冲区溢出NessusSCADA2010/12/222026/9/10
high
58796Microsys PROMOTIC 检测NessusSCADA2012/4/192026/9/10
info
84586Trihedral VTScada 检测NessusSCADA2015/7/72026/9/10
info
88416iniNet SpiderControl SCADA Web Server 2.02 本地权限升级NessusSCADA2016/1/272026/9/10
high
58991RuggedCom RuggedOS 默认“factory”帐户后门NessusSCADA2012/6/122026/9/14
critical
23816Tamarack IEEE 61850 伺服器偵測NessusSCADA2006/12/112025/7/14
info
23823Modicon PLC CPU 類型 SNMP 要求模型類型遠端洩漏NessusSCADA2006/12/112026/4/8
medium
23824Modicon PLC IO 掃描狀態 SNMP 要求掃描狀態遠端洩漏NessusSCADA2006/12/112026/4/8
medium
52994Movicon TcpUploadServer 偵測NessusSCADA2011/3/252025/9/29
info
542917-Technologies IGSS < 9.0.0.11129 多個 DoS 弱點NessusSCADA2011/5/162025/7/14
medium
65193CoDeSys Gateway Service 偵測NessusSCADA2013/3/112025/9/29
info
77374Honeywell Excel (XL) Web 控制器偵測NessusSCADA2014/8/252025/7/14
info
872087-Technologies / Schneider-Electric IGSS Data Collector 偵測NessusSCADA2015/12/42025/9/29
info
890297-Technologies / Schneider-Electric IGSS ODBC 服務偵測NessusSCADA2016/2/292025/9/29
info
91623Cogent DataHub < 6.4.5Beta OPC 連線失敗 DoSNessusSCADA2016/6/152025/7/14
medium
23820Modicon PLC 內嵌 HTTP 伺服器偵測NessusSCADA2006/12/112026/8/10
medium
23822Modicon Quantum HTTP 伺服器預設憑證NessusSCADA2006/12/112026/8/10
high
67143Tridium Niagara AX Web Server 目錄遊走「config.bog」洩漏遠端入侵NessusSCADA2013/7/32026/8/10
high
80359StruxureWare SCADA Expert ClearSCADA 遠端安全性繞過NessusSCADA2015/1/52026/8/10
medium
90599Rockwell Automation MicroLogix 1400 PLC 預設認證NessusSCADA2016/4/202026/8/10
critical
50687RealWin < 2.1.10 多個封包類型處理溢位NessusSCADA2010/11/232025/7/14
critical
66805CoDeSys Gateway Service < 2.3.9.28 釋放後使用NessusSCADA2013/6/52025/7/14
critical
58953Microsys PROMOTIC < 8.1.5 多個弱點NessusSCADA2012/5/12025/7/14
high
592497-Technologies IGSS < 9.0.0.11291 DLL 載入任意程式碼執行NessusSCADA2012/5/232025/7/14
high
59559Measuresoft ScadaPro 路徑 Subversion 任意 DLL 插入程式碼執行NessusSCADA2012/6/182025/7/14
high
63430Siemens Automation License Manager CVE-2012-4691 拒絕服務NessusSCADA2013/1/92025/7/14
low
52962IGSS 資料伺服器目錄遊走任意檔案存取NessusSCADA2011/3/242025/9/29
medium
546457-Technologies IGSS < 9.0.0.11143 ODBC 遠端記憶體損毀NessusSCADA2011/5/252025/7/14
critical
72107Ecava IntegraXor < 4.1.4369 專案目錄資訊洩漏NessusSCADA2014/1/232025/7/14
medium
70530Siemens SCALANCE X-200 驗證繞過NessusSCADA2013/10/212025/7/14
critical