88414 | iniNet SpiderControl PLC Editor Simatic 6.30.04 本機權限提升 | Nessus | SCADA | 2016/1/27 | 2025/7/14 | high |
88415 | iniNet SpiderControl SCADA Editor 6.30.01 本機權限提升 | Nessus | SCADA | 2016/1/27 | 2025/7/14 | high |
89029 | 7-Technologies / Schneider-Electric IGSS ODBC 服務偵測 | Nessus | SCADA | 2016/2/29 | 2025/7/14 | info |
89030 | 7-Technologies IGSS < 9.0.0.11143 ODBC 無效結構 RCE | Nessus | SCADA | 2016/2/29 | 2025/7/14 | critical |
89031 | 7-Technologies IGSS < 10.0.0 ODBC 緩衝區溢位 RCE | Nessus | SCADA | 2016/2/29 | 2025/7/14 | critical |
91284 | Moxa NPort Serial-to-Ethernet 伺服器多個弱點 | Nessus | SCADA | 2016/5/20 | 2025/7/14 | critical |
91384 | MicroLogix 1400 PLC Web 伺服器多個弱點 | Nessus | SCADA | 2016/5/31 | 2025/7/14 | high |
47759 | Siemens SIMATIC WinCC 預設密碼驗證繞過 | Nessus | SCADA | 2010/7/16 | 2025/7/21 | high |
51360 | Ecava IntegraXor ActiveX 的儲存方法有緩衝區溢位 | Nessus | SCADA | 2010/12/22 | 2025/7/21 | high |
52961 | 7-Technologies / Schneider-Electric IGSS 偵測 | Nessus | SCADA | 2011/3/24 | 2025/7/21 | info |
53572 | 自動化解決方案 Modbus/TCP OPC 伺服器偵測 | Nessus | SCADA | 2011/4/27 | 2025/7/21 | info |
56993 | Advantech / BroadWin WebAccess Client「bwocxrun.ocx」多個遠端弱點 | Nessus | SCADA | 2011/12/2 | 2025/7/21 | high |
58449 | 7-Technologies AQUIS 不明路徑 Subversion 任意 DLL 插入程式碼執行 | Nessus | SCADA | 2012/3/23 | 2025/7/21 | high |
58796 | Microsys PROMOTIC 偵測 | Nessus | SCADA | 2012/4/19 | 2025/7/21 | info |
59892 | WellinTech KingHistorian 偵測 | Nessus | SCADA | 2012/7/6 | 2025/7/21 | info |
62964 | IOServer 偵測 | Nessus | SCADA | 2012/11/19 | 2025/7/21 | info |
63427 | Siemens Automation License Manager 偵測 | Nessus | SCADA | 2013/1/9 | 2025/7/21 | info |
65656 | Honeywell 多個產品 HscRemoteDepoy.dll ActiveX 控制項任意程式碼執行 | Nessus | SCADA | 2013/3/22 | 2025/7/21 | medium |
70591 | KEPServerEX 偵測 | Nessus | SCADA | 2013/10/24 | 2025/7/21 | info |
73646 | Advantech WebAccess webvact ActiveX 多個緩衝區溢位弱點 | Nessus | SCADA | 2014/4/14 | 2025/7/21 | high |
81789 | Siemens SIMATIC STEP 7 (TIA Portal) V13 偵測 | Nessus | SCADA | 2015/3/12 | 2025/7/21 | info |
83187 | Schneider Electric OPC Factory Server (OFS) < 3.5 SP1 ActiveX 物件多個緩衝區溢位 DoS | Nessus | SCADA | 2015/5/1 | 2025/7/21 | high |
117360 | Advantech WebAccess webvrpcs.exe 路徑遊走 RCE | Nessus | SCADA | 2018/9/10 | 2025/7/21 | critical |
124329 | Advantech WebAccess webvrpcs.exe 任意檔案下載 | Nessus | SCADA | 2019/4/26 | 2025/7/21 | high |
97666 | Siemens SIMATIC Logon 驗證繞過 | Nessus | SCADA | 2017/3/10 | 2025/7/21 | critical |
97667 | Siemens SIMATIC 登入偵測 | Nessus | SCADA | 2017/3/10 | 2025/7/21 | info |
103048 | Advantech WebAccess < 8.2_20170817 多個弱點 | Nessus | SCADA | 2017/9/8 | 2025/7/14 | critical |
112123 | Siemens Automation License Manager 5.x < 5.3.4.4 多個弱點 | Nessus | SCADA | 2018/8/27 | 2025/7/14 | high |
112124 | Siemens Automation License Manager 6.x < 6.0.1 目錄遊走 | Nessus | SCADA | 2018/8/27 | 2025/7/14 | high |
125312 | Rockwell Automation MicroLogix 1100/1400 和 CompactLogix 5370 控制器開放重新導向弱點 | Nessus | SCADA | 2019/5/21 | 2025/7/14 | medium |
127139 | 3S CODESYS V3 CmpUserMgr 3.x < 3.5.16.0 密碼傳輸弱點 | Nessus | SCADA | 2019/8/12 | 2025/7/14 | high |
131402 | Siemens SINEMA Remote Connect Server 多個弱點 (SSA-884497) | Nessus | SCADA | 2019/12/2 | 2025/7/14 | critical |
152099 | CODESYS V2 Web 伺服器偵測 | Nessus | SCADA | 2021/7/27 | 2025/7/14 | info |
91345 | Allen-Bradley MicroLogix 1400 多個弱點 | Nessus | SCADA | 2016/5/27 | 2025/7/14 | critical |
23801 | Matrikon OPC Explorer 偵測 | Nessus | SCADA | 2006/12/11 | 2025/7/21 | info |
23967 | ICONICS 對話方塊包裝模組 ActiveX (DlgWrapper.dll) DoModal 函式溢位 | Nessus | SCADA | 2007/1/3 | 2025/7/21 | high |
52993 | Movicon < 11.2 Build 1084 多個弱點 | Nessus | SCADA | 2011/3/25 | 2025/7/14 | high |
23804 | Siemens SIMATIC PDM 偵測 | Nessus | SCADA | 2006/12/11 | 2025/7/21 | info |
152099 | CODESYS V2 Webサーバーの検出 | Nessus | SCADA | 2021/7/27 | 2025/7/14 | info |
23809 | DNP3 バイナリ入力アクセスリモート情報漏洩 | Nessus | SCADA | 2006/12/11 | 2025/7/14 | medium |
23811 | ICCP/COTP(ISO 8073)プロトコル検出 | Nessus | SCADA | 2006/12/11 | 2025/7/14 | high |
23830 | OPC Historical Data Access (HDA) サーバーの検出 | Nessus | SCADA | 2006/12/11 | 2025/7/14 | info |
53573 | Modbus/TCP Master OPC Server MODBUSプロトコル応答パケットのリモートオーバーフロー | Nessus | SCADA | 2011/4/27 | 2025/7/14 | high |
57598 | GE D20 のデフォルトの認証情報 | Nessus | SCADA | 2012/1/19 | 2025/7/14 | high |
57602 | GE D20 Remote Terminal Unit から、TFTP を通じて、機密情報を入手することができます | Nessus | SCADA | 2012/1/19 | 2025/7/14 | high |
58991 | RuggedCom RuggedOS のデフォルトの「factory」アカウントのバックドア | Nessus | SCADA | 2012/6/12 | 2025/7/14 | critical |
59249 | 7-Technologies IGSS < 9.0.0.11291 の DLL 読み込みにおける任意のコードの実行 | Nessus | SCADA | 2012/5/23 | 2025/7/14 | high |
59528 | RuggedCom RuggedOS の Web ベースの管理インターフェイスのデフォルト認証情報 | Nessus | SCADA | 2012/6/15 | 2025/7/14 | critical |
61493 | Sielco Sistemi Winlog における任意のファイルの漏洩 | Nessus | SCADA | 2012/8/10 | 2025/7/14 | medium |
62439 | Magnum MNS-6K ハードコードされた管理者アカウント | Nessus | SCADA | 2012/10/5 | 2025/7/14 | high |