84263 | Schneider Electric InduSoft Web Studio < 7.1.3.4 多种信息泄漏 (SEVD-2015-054-01) | Nessus | SCADA | 2015/6/18 | 2025/7/14 | medium |
85600 | Advantech WebAccess 7.2 < 7.2-2014.07.30 多个 ActiveX RCE | Nessus | SCADA | 2015/8/24 | 2025/7/14 | medium |
85543 | Advantech WebAccess < 7.0-2011.08.27 多种 ActiveX RCE | Nessus | SCADA | 2015/8/19 | 2025/7/14 | medium |
91283 | Moxa NPort Serial-to-Ethernet 服务器检测 | Nessus | SCADA | 2016/5/20 | 2025/7/14 | info |
83301 | Modbus/TCP 设备标识 | Nessus | SCADA | 2015/5/10 | 2025/7/14 | medium |
83264 | Siemens SCALANCE S612 Firewall 检测 | Nessus | SCADA | 2015/5/6 | 2025/7/14 | info |
23829 | OPC 数据访问 (DA) 服务器检测 | Nessus | SCADA | 2006/12/11 | 2025/7/14 | info |
23803 | National Instruments Lookout 检测 | Nessus | SCADA | 2006/12/11 | 2025/7/21 | info |
23807 | Siemens-Telegr ICCP 网关检测 | Nessus | SCADA | 2006/12/11 | 2025/7/21 | info |
23808 | DNP3 链路层暴力破解寻址泄露 | Nessus | SCADA | 2006/12/11 | 2025/7/14 | medium |
23823 | Modicon PLC CPU 类型 SNMP 请求型号类型远程泄露 | Nessus | SCADA | 2006/12/11 | 2025/7/25 | medium |
97436 | Modicon Modbus/TCP UnityPro 编程功能代码访问 | Nessus | SCADA | 2017/2/28 | 2025/7/14 | medium |
95713 | 已安装 Siemens SINEMA Server | Nessus | SCADA | 2016/12/12 | 2025/7/21 | info |
131704 | 3S CODESYS CmpWebServerHandlerV3 基于堆的缓冲区溢出 | Nessus | SCADA | 2019/12/4 | 2025/7/14 | critical |
136182 | 3S CODESYS Runtime 3.x < 3.5.15.40 中存在多个漏洞 | Nessus | SCADA | 2020/4/30 | 2025/7/14 | critical |
149307 | CodeMeter Runtime 可预测的加密密钥 | Nessus | SCADA | 2021/5/6 | 2025/7/21 | critical |
149971 | Schneider Electric C-Gate < 2.11.6 多个漏洞 | Nessus | SCADA | 2021/5/26 | 2025/7/14 | high |
103533 | Trihedral VTScada 8.x < 11.2.02 中存在多个漏洞 | Nessus | SCADA | 2017/9/28 | 2025/7/14 | critical |
103534 | Trihedral VTScada 检测 | Nessus | SCADA | 2017/9/28 | 2025/7/14 | info |
106228 | Schneider Electric InduSoft Web Studio / InTouch Machine Edition < 8.1 中存在 RCE 漏洞 | Nessus | SCADA | 2018/1/22 | 2025/7/14 | critical |
118711 | DNP3 设备检测属性 | Nessus | SCADA | 2018/11/2 | 2025/7/14 | info |
119845 | Advantech WebAccess webvrpcs.exe IOCTL 70022 堆栈溢出 | Nessus | SCADA | 2018/12/21 | 2025/7/21 | high |
109145 | Schneider Electric InTouch Machine Edition 检测 | Nessus | SCADA | 2018/4/18 | 2025/7/21 | info |
109146 | Schneider Electric InduSoft Web Studio 检测 | Nessus | SCADA | 2018/4/18 | 2025/7/21 | info |
26066 | 自动化解决方案 Modbus Slave MiniHMI.exe ActiveX Modbus/TCP 诊断功能 任意代码执行 | Nessus | SCADA | 2007/9/19 | 2025/7/21 | high |
50687 | RealWin < 2.1.10 多种数据包类型处理溢出 | Nessus | SCADA | 2010/11/23 | 2025/7/14 | critical |
53878 | Samsung Data Management Server 的“root”帐户默认密码 (rkwjsdusrnth) | Nessus | SCADA | 2011/5/11 | 2025/7/14 | critical |
23810 | DNP3 分站非请求消息传递支持 | Nessus | SCADA | 2006/12/11 | 2025/7/14 | medium |
23815 | SISCO OSI/ICCP 堆栈检测 | Nessus | SCADA | 2006/12/11 | 2025/7/21 | info |
23817 | Modbus/TCP Coil Access | Nessus | SCADA | 2006/12/11 | 2025/7/14 | medium |
23819 | Modicon Modbus/TCP 编程功能代码访问 | Nessus | SCADA | 2006/12/11 | 2025/7/14 | medium |
23821 | Schneider Electric FTP 服务器默认凭据 | Nessus | SCADA | 2006/12/11 | 2025/7/14 | critical |
23826 | Modicon PLC Web 密码状态泄露 SNMP 请求密码状态远程泄露 | Nessus | SCADA | 2006/12/11 | 2025/7/25 | medium |
60084 | Advantech Studio ISSymbol ActiveX 控件多种缓冲区溢出漏洞 | Nessus | SCADA | 2012/7/20 | 2025/7/21 | high |
57601 | SEL 控制器默认凭据 | Nessus | SCADA | 2012/1/19 | 2025/7/14 | high |
59556 | Measuresoft ScadaPro 检测 | Nessus | SCADA | 2012/6/18 | 2025/7/21 | info |
59557 | Measuresoft ScadaPro < 4.0.1.0 service.exe RF 命令任意文件泄露 | Nessus | SCADA | 2012/6/18 | 2025/7/14 | critical |
59374 | WellinTech KingView 检测 | Nessus | SCADA | 2012/6/5 | 2025/7/21 | info |
59375 | WellinTech KingView 6.53 < 2010-12-15 HistorySvr.exe TCP 请求远程溢出 | Nessus | SCADA | 2012/6/5 | 2025/7/21 | critical |
152098 | CODESYS V2 Web 服务器未正确实现安全检查 (2021-07) | Nessus | SCADA | 2021/7/27 | 2025/7/14 | critical |
55630 | Sielco Sistemi Winlog 检测 | Nessus | SCADA | 2011/7/19 | 2025/7/21 | info |
58797 | Microsys PROMOTIC 项目文件处理释放后使用远程代码执行 | Nessus | SCADA | 2012/4/19 | 2025/7/14 | high |
58448 | 7-Technologies AQUIS 检测 | Nessus | SCADA | 2012/3/23 | 2025/7/21 | info |
58451 | 7-Technologies TERMIS 不明路径 Subversion 任意 DLL 注入代码执行 | Nessus | SCADA | 2012/3/23 | 2025/7/21 | high |
62797 | CoDeSys 未经认证的命令行访问 | Nessus | SCADA | 2012/11/2 | 2025/7/14 | critical |
63429 | Siemens Automation License Manager“almaxcx.dll”ActiveX 任意文件覆盖漏洞 | Nessus | SCADA | 2013/1/9 | 2025/7/21 | medium |
64682 | Siemens SIMATIC RF-MANAGER 检测 | Nessus | SCADA | 2013/2/19 | 2025/7/21 | info |
73567 | BACnet 协议检测 | Nessus | SCADA | 2014/4/16 | 2025/7/14 | info |
72702 | StruxureWare SCADA Expert ClearSCADA 检测 | Nessus | SCADA | 2014/2/26 | 2025/7/21 | info |
72708 | Mitsubishi Electric Automation MC-WorX 8.x ActiveX 控件远程代码执行 | Nessus | SCADA | 2014/2/26 | 2025/7/21 | high |