| 81577 | Siemens SIMATIC WinCC (TIA Portal) V13 偵測 | Nessus | SCADA | 2015/3/1 | 2026/5/13 | info |
| 81789 | Siemens SIMATIC STEP 7 (TIA Portal) V13 偵測 | Nessus | SCADA | 2015/3/12 | 2026/5/13 | info |
| 122424 | CODESYS V3 執行階段服務偵測 | Nessus | SCADA | 2019/2/26 | 2026/5/13 | info |
| 53548 | Ecava IntegraXor 偵測 | Nessus | SCADA | 2011/4/25 | 2026/5/13 | info |
| 55630 | Sielco Sistemi Winlog 偵測 | Nessus | SCADA | 2011/7/19 | 2026/5/13 | info |
| 59374 | WellinTech KingView 偵測 | Nessus | SCADA | 2012/6/5 | 2026/5/13 | info |
| 70591 | KEPServerEX 偵測 | Nessus | SCADA | 2013/10/24 | 2026/5/13 | info |
| 84498 | Siemens SIMATIC ProSave 偵測 | Nessus | SCADA | 2015/7/2 | 2026/5/13 | info |
| 88412 | iniNet SpiderControl SCADA Editor 偵測 | Nessus | SCADA | 2016/1/27 | 2026/5/13 | info |
| 97667 | Siemens SIMATIC 登入偵測 | Nessus | SCADA | 2017/3/10 | 2026/5/13 | info |
| 56993 | Advantech / BroadWin WebAccess Client「bwocxrun.ocx」多個遠端弱點 | Nessus | SCADA | 2011/12/2 | 2026/5/13 | high |
| 59375 | WellinTech KingView 6.53 < 2010-12-15 HistorySvr.exe TCP 要求遠端溢位 | Nessus | SCADA | 2012/6/5 | 2026/5/13 | critical |
| 59377 | WellinTech KingView 6.53 < 2012-03-22 多個弱點 | Nessus | SCADA | 2012/6/5 | 2026/5/13 | critical |
| 134977 | 3S CODESYS Runtime 3.x < 3.5.14.20 多個弱點 | Nessus | SCADA | 2020/3/30 | 2026/4/16 | critical |
| 137356 | Inductive Automation Ignition 8.x < 8.0.10 多個弱點 | Nessus | SCADA | 2020/6/11 | 2026/4/16 | high |
| 136182 | 3S CODESYS Runtime 3.x < 3.5.15.40 多個弱點 | Nessus | SCADA | 2020/4/30 | 2026/4/16 | critical |
| 99168 | Siemens S7 通訊協定支援偵測 | Nessus | SCADA | 2017/4/3 | 2025/9/29 | info |
| 119147 | Modicon Quantum HTTP 伺服器 'formTest' 'name' 參數 XSS | Nessus | SCADA | 2018/11/26 | 2026/3/23 | medium |
| 129292 | Advantech WebAccess webvprcs IOCTL 70603 堆疊溢位 | Nessus | SCADA | 2019/9/24 | 2026/5/13 | critical |
| 65195 | CoDeSys Gateway Service < 2.3.9.27 多個弱點 | Nessus | SCADA | 2013/3/11 | 2025/7/14 | critical |
| 65656 | Honeywell 多個產品 HscRemoteDepoy.dll ActiveX 控制項任意程式碼執行 | Nessus | SCADA | 2013/3/22 | 2026/5/13 | medium |
| 73641 | Advantech WebAccess 多個 BWOCXRUN.OCX ActiveX 弱點 | Nessus | SCADA | 2014/4/14 | 2026/5/13 | high |
| 88839 | Advantech WebAccess openWidget 指令碼路徑遊走遠端檔案洩漏 | Nessus | SCADA | 2016/2/18 | 2026/3/23 | high |
| 76147 | Cogent DataHub < 7.3.5 多個弱點 | Nessus | SCADA | 2014/6/19 | 2025/7/14 | high |
| 95716 | Siemens SIMATIC WinCC (TIA Portal) < 14 無引號服務路徑本機權限提升 (SSA-701708) | Nessus | SCADA | 2016/12/12 | 2026/5/13 | medium |
| 83952 | Inductive Automation Ignition 多個弱點 | Nessus | SCADA | 2015/6/2 | 2026/3/23 | medium |
| 131736 | CODESYS ENI 伺服器 < 3.2.2.25 堆疊溢位 (經認證的檢查) | Nessus | SCADA | 2019/12/6 | 2026/4/16 | critical |
| 149522 | PTC OPC UA 伺服器的多個弱點 | Nessus | SCADA | 2021/5/17 | 2025/9/29 | critical |
| 100462 | GE Multilin UR / URPlus / B95Plus 保護轉送密碼編譯演算法弱點資訊洩漏 (UR-2017-0001) | Nessus | SCADA | 2017/5/26 | 2025/7/14 | critical |
| 123010 | Rockwell Automation RSLinx Classic ENGINE.dll 堆疊緩衝區溢位 (CVE-2019-6553) | Nessus | SCADA | 2019/3/22 | 2025/9/29 | critical |
| 55025 | Ecava IntegraXor < 3.60.4080 XSS | Nessus | SCADA | 2011/6/9 | 2025/7/14 | medium |
| 58449 | 7-Technologies AQUIS 不明路徑 Subversion 任意 DLL 插入程式碼執行 | Nessus | SCADA | 2012/3/23 | 2026/5/13 | high |
| 64630 | Ecava IntegraXor < 4.00.4283 ActiveX 遠端緩衝區溢位 | Nessus | SCADA | 2013/2/14 | 2025/7/14 | high |
| 70416 | ProSoft RadioLinx ControlScape PRNG 弱點 | Nessus | SCADA | 2013/10/14 | 2025/7/14 | high |
| 73517 | RuggedCom RuggedOS HTTP 流量處理遠端 DoS | Nessus | SCADA | 2014/4/15 | 2026/3/23 | medium |
| 82076 | Meinberg LANTIME Web 介面的不明 XSS | Nessus | SCADA | 2015/3/25 | 2025/7/14 | medium |
| 58451 | 7-Technologies TERMIS 不明路徑 Subversion 任意 DLL 插入程式碼執行 | Nessus | SCADA | 2012/3/23 | 2026/5/13 | high |
| 60084 | Advantech Studio ISSymbol ActiveX 控制項多個緩衝區溢位弱點 | Nessus | SCADA | 2012/7/20 | 2026/5/13 | high |
| 62032 | Sielco Sistemi Winlog < 2.07.17 多個弱點 | Nessus | SCADA | 2012/9/10 | 2025/7/14 | high |
| 70592 | KEPServerEX < 5.12.140.0 拒絕服務 | Nessus | SCADA | 2013/10/24 | 2025/7/14 | high |
| 72708 | Mitsubishi Electric Automation MC-WorX 8.x ActiveX 控制項遠端程式碼執行 | Nessus | SCADA | 2014/2/26 | 2026/5/13 | high |
| 73516 | RuggedCom RuggedOS SNMP 通訊協定不明 DoS | Nessus | SCADA | 2014/4/15 | 2025/7/14 | high |
| 81578 | Siemens SIMATIC WinCC (TIA Portal) < 1300.100.2201.15 多個弱點 (SSA-543623) | Nessus | SCADA | 2015/3/1 | 2025/9/29 | high |
| 84499 | Siemens SIMATIC ProSave < 1300.100.2201.15 未受信任的路徑任意程式碼執行 (SSA-451236) | Nessus | SCADA | 2015/7/2 | 2025/9/29 | medium |
| 84570 | Rockwell Automation MicroLogix 1100 PLC < FRN 10.0 驗證機制 DoS | Nessus | SCADA | 2015/7/7 | 2026/3/23 | critical |
| 89030 | 7-Technologies IGSS < 9.0.0.11143 ODBC 無效結構 RCE | Nessus | SCADA | 2016/2/29 | 2025/7/14 | critical |
| 109280 | Schneider Electric InduSoft Web Studio / InTouch Machine Edition Opcode 50 mbstowcs() 堆疊溢位 | Nessus | SCADA | 2018/4/23 | 2025/9/29 | critical |
| 85691 | Advantech WebAccess < 7.0-2009.06.29 多個弱點 | Nessus | SCADA | 2015/8/28 | 2026/3/23 | critical |
| 106229 | AVEVA InduSoft Web Studio/InTouch Edge HMI TCP/IP 伺服器偵測 | Nessus | SCADA | 2018/1/22 | 2025/9/29 | info |
| 111139 | RedLion Crimson 通訊協定偵測 | Nessus | SCADA | 2018/7/17 | 2025/9/29 | info |