| 87891 | Janitza 多個 UMG 裝置遠端除錯介面 RCE | Nessus | SCADA | 2016/1/13 | 2025/7/14 | high |
| 89031 | 7-Technologies IGSS < 10.0.0 ODBC 緩衝區溢位 RCE | Nessus | SCADA | 2016/2/29 | 2025/7/14 | critical |
| 83467 | 使用中物件類別的 EtherNet/IP CIP 清單 | Nessus | SCADA | 2015/5/14 | 2025/9/29 | info |
| 94329 | OMRON FINS TCP 通訊協定偵測 | Nessus | SCADA | 2016/10/27 | 2026/7/17 | info |
| 23807 | Siemens-Telegr ICCP 閘道偵測 | Nessus | SCADA | 2006/12/11 | 2026/9/10 | info |
| 23803 | National Instruments Lookout 偵測 | Nessus | SCADA | 2006/12/11 | 2026/9/10 | info |
| 23805 | Siemens S7-SCL 開發工具偵測 | Nessus | SCADA | 2006/12/11 | 2026/9/10 | info |
| 49694 | BACnet OPC Client < 1.0.25 緩衝區溢位 | Nessus | SCADA | 2010/9/24 | 2026/9/10 | high |
| 52051 | Moxa Device Manager Tool MDM2_Gateway 回應遠端溢位 | Nessus | SCADA | 2011/2/21 | 2026/9/10 | high |
| 64683 | Siemens SIMATIC RF-MANAGER KeyHelp.ocx 緩衝區溢位 | Nessus | SCADA | 2013/2/19 | 2026/9/10 | medium |
| 73303 | Ecava IntegraXor < 4.1.4410 資訊洩漏 | Nessus | SCADA | 2014/4/2 | 2026/9/10 | medium |
| 76575 | Triangle MicroWorks SCADA Data Gateway < 3.3.729 活動訊號資訊洩漏 (Heartbleed) | Nessus | SCADA | 2014/7/7 | 2026/9/10 | high |
| 81593 | Siemens SIMATIC S7-1200 PLC Web 伺服器偵測 | Nessus | SCADA | 2015/3/2 | 2026/9/10 | info |
| 81701 | Advantech ADAMView 安裝偵測 | Nessus | SCADA | 2015/3/9 | 2026/9/10 | info |
| 85600 | Advantech WebAccess 7.2 < 7.2-2014.07.30 多個 ActiveX RCE | Nessus | SCADA | 2015/8/24 | 2026/9/10 | medium |
| 89111 | Advantech WebAccess < 8.1-2015.12.30 多個弱點 | Nessus | SCADA | 2016/3/3 | 2026/9/10 | high |
| 91625 | Panasonic Control FPWIN Pro 偵測 | Nessus | SCADA | 2016/6/15 | 2026/9/10 | info |
| 120947 | 3S CODESYS Runtime 3.x < 3.5.14.0 存取控制不足弱點 | Nessus | SCADA | 2019/1/3 | 2026/9/10 | critical |
| 124591 | Advantech WebAccess webvrpcs.exe 0x138bd IOCTL RCE | Nessus | SCADA | 2019/5/3 | 2026/9/10 | critical |
| 151191 | Johnson Controls exacqVision Web Service 資訊洩漏 (JCI-PSA-2021-03) | Nessus | SCADA | 2021/6/30 | 2026/9/10 | high |
| 23799 | Areva/Alstom Energy Management System 偵測 | Nessus | SCADA | 2006/12/11 | 2026/9/10 | info |
| 58448 | 7-Technologies AQUIS 偵測 | Nessus | SCADA | 2012/3/23 | 2026/9/10 | info |
| 59500 | WellinTech KingOPCServer 偵測 | Nessus | SCADA | 2012/6/14 | 2026/9/10 | info |
| 73645 | Advantech WebAccess Web 系統管理介面偵測 | Nessus | SCADA | 2014/4/14 | 2026/9/10 | info |
| 76574 | Triangle MicroWorks SCADA Data Gateway < 3.0.635 多個 DoS 弱點 | Nessus | SCADA | 2014/7/17 | 2026/9/10 | medium |
| 80910 | Honeywell OPOS Suite 堆疊緩衝區溢位 | Nessus | SCADA | 2015/1/22 | 2026/9/10 | high |
| 81553 | WellinTech KingSCADA < 3.1.2.13-EN 'kxNetDispose.dll' 緩衝區溢位 RCE | Nessus | SCADA | 2015/2/26 | 2026/9/10 | critical |
| 84263 | Schneider Electric InduSoft Web Studio < 7.1.3.4 多個資訊洩漏 (SEVD-2015-054-01) | Nessus | SCADA | 2015/6/18 | 2026/9/10 | medium |
| 117671 | Rockwell Automation RSLinx Classic <= 4.00.01 多個弱點 | Nessus | SCADA | 2018/9/24 | 2026/9/10 | critical |
| 133216 | Siemens SIMATIC STEP 7 的 TIA Portal 中有本機權限提升弱點 (SSA-629512) | Nessus | SCADA | 2020/1/24 | 2026/9/10 | high |
| 149971 | Schneider Electric C-Gate < 2.11.6 多個弱點 | Nessus | SCADA | 2021/5/26 | 2026/9/10 | high |
| 59527 | RuggedCom RuggedOS (ROS) Web 型管理介面偵測 | Nessus | SCADA | 2012/6/15 | 2026/9/10 | info |
| 59556 | Measuresoft ScadaPro 偵測 | Nessus | SCADA | 2012/6/18 | 2026/9/10 | info |
| 70292 | WellinTech KingView ActiveX 多個任意檔案覆寫弱點 | Nessus | SCADA | 2013/10/3 | 2026/9/10 | medium |
| 70558 | ClearSCADA Web 伺服器偵測 | Nessus | SCADA | 2013/10/23 | 2026/9/10 | info |
| 73644 | Advantech WebAccess 預設認證檢查 | Nessus | SCADA | 2014/4/14 | 2026/9/10 | high |
| 77964 | Ecava IntegraXor < 4.2.4458 多個弱點 | Nessus | SCADA | 2014/9/29 | 2026/9/10 | high |
| 88413 | iniNet SpiderControl PLC Editor Beckhoff 6.30.04 本機權限提升 | Nessus | SCADA | 2016/1/27 | 2026/9/10 | high |
| 90001 | PACTware 偵測 | Nessus | SCADA | 2016/3/17 | 2026/9/10 | info |
| 90002 | PACTware 4.1 SP3 (4.1.0.42) 處理檔案處理錯誤時發生 DoS | Nessus | SCADA | 2016/3/17 | 2026/9/10 | medium |
| 96876 | Advantech WebAccess SQLi | Nessus | SCADA | 2017/1/30 | 2026/9/10 | critical |
| 100299 | Siemens SIMATIC WinCC (TIA Portal) 13 < 13 SP2 / 14 < 14 SP1 多個 DoS | Nessus | SCADA | 2017/5/19 | 2026/9/10 | medium |
| 103048 | Advantech WebAccess < 8.2_20170817 多個弱點 | Nessus | SCADA | 2017/9/8 | 2026/9/10 | critical |
| 117360 | Advantech WebAccess webvrpcs.exe 路徑遊走 RCE | Nessus | SCADA | 2018/9/10 | 2026/9/10 | critical |
| 23967 | ICONICS 對話方塊包裝模組 ActiveX (DlgWrapper.dll) DoModal 函式溢位 | Nessus | SCADA | 2007/1/3 | 2026/9/10 | high |
| 59528 | RuggedCom RuggedOS Web 型管理介面預設認證 | Nessus | SCADA | 2012/6/15 | 2026/9/10 | critical |
| 70351 | RuggedCom RuggedOS < 3.12.2 多個弱點 | Nessus | SCADA | 2013/10/7 | 2026/9/10 | high |
| 95715 | Siemens SIMATIC STEP 7 (TIA Portal) < 14 無引號服務路徑本機權限提升 (SSA-701708) | Nessus | SCADA | 2016/12/12 | 2026/9/10 | medium |
| 111139 | RedLion Crimson 协议检测 | Nessus | SCADA | 2018/7/17 | 2025/9/29 | info |
| 118711 | DNP3 设备检测属性 | Nessus | SCADA | 2018/11/2 | 2025/9/29 | info |