| 91283 | Moxa NPort Serial-to-Ethernet 服务器检测 | Nessus | SCADA | 2016/5/20 | 2025/7/14 | info |
| 91384 | MicroLogix 1400 PLC Web 服务器多种漏洞 | Nessus | SCADA | 2016/5/31 | 2026/3/23 | high |
| 91622 | Cogent DataHub < 6.4.3 OPC 客户端重新连接饱和远程 DoS | Nessus | SCADA | 2016/6/15 | 2025/7/14 | medium |
| 96876 | Advantech WebAccess SQLi | Nessus | SCADA | 2017/1/30 | 2026/3/23 | critical |
| 129469 | 3S CODESYS V3 CmpWebServer 多个漏洞 | Nessus | SCADA | 2019/9/30 | 2026/3/23 | critical |
| 72620 | TURCK BL20/BL67 硬编码管理员帐户 | Nessus | SCADA | 2014/2/10 | 2026/6/15 | critical |
| 77964 | Ecava IntegraXor < 4.2.4458 多种漏洞 | Nessus | SCADA | 2014/9/29 | 2025/9/29 | high |
| 103048 | Advantech WebAccess < 8.2_20170817 中存在多个漏洞 | Nessus | SCADA | 2017/9/8 | 2026/3/23 | critical |
| 87891 | Janitza 多个 UMG 设备远程调试接口 RCE | Nessus | SCADA | 2016/1/13 | 2025/7/14 | high |
| 70351 | RuggedCom RuggedOS < 3.12.2 多种漏洞 | Nessus | SCADA | 2013/10/7 | 2026/3/23 | high |
| 83263 | Siemens SCALANCE S612 Firewall > 2.1 和 < 2.3.0.3 中存在多个漏洞 (SSA-268149) | Nessus | SCADA | 2015/5/6 | 2026/3/23 | critical |
| 85600 | Advantech WebAccess 7.2 < 7.2-2014.07.30 多个 ActiveX RCE | Nessus | SCADA | 2015/8/24 | 2026/3/23 | medium |
| 89111 | Advantech WebAccess < 8.1-2015.12.30 多种漏洞 | Nessus | SCADA | 2016/3/3 | 2026/3/23 | high |
| 89031 | 7-Technologies IGSS < 10.0.0 ODBC 缓冲区溢出 RCE | Nessus | SCADA | 2016/2/29 | 2025/7/14 | critical |
| 100299 | Siemens SIMATIC WinCC (TIA Portal) 13 < 13 SP2 / 14 < 14 SP1 多个 DoS | Nessus | SCADA | 2017/5/19 | 2025/9/29 | medium |
| 106228 | Schneider Electric InduSoft Web Studio / InTouch Machine Edition < 8.1 中存在 RCE 漏洞 | Nessus | SCADA | 2018/1/22 | 2025/11/3 | critical |
| 81592 | Siemens SIMATIC S7-1200 PLC < 4.1 中存在开放重定向 | Nessus | SCADA | 2015/3/2 | 2025/7/14 | medium |
| 53877 | Samsung Data Management Server < 1.4.3 verifyUser 方法 SQL 注入 | Nessus | SCADA | 2011/5/11 | 2026/3/23 | high |
| 76574 | Triangle MicroWorks SCADA Data Gateway < 3.0.635 多个 DoS 漏洞 | Nessus | SCADA | 2014/7/17 | 2025/9/29 | medium |
| 130430 | CODESYS Gateway V3 DoS | Nessus | SCADA | 2019/10/31 | 2025/9/29 | high |
| 61493 | Sielco Sistemi Winlog 任意文件泄露 | Nessus | SCADA | 2012/8/10 | 2025/7/14 | medium |
| 23967 | ICONICS Dialog Wrapper Module ActiveX (DlgWrapper.dll) DoModal 函数溢出 | Nessus | SCADA | 2007/1/3 | 2026/7/17 | high |
| 52051 | Moxa Device Manager Tool MDM2_Gateway 响应远程溢出 | Nessus | SCADA | 2011/2/21 | 2026/7/17 | high |
| 59556 | Measuresoft ScadaPro 检测 | Nessus | SCADA | 2012/6/18 | 2026/7/17 | info |
| 91625 | Panasonic Control FPWIN Pro 检测 | Nessus | SCADA | 2016/6/15 | 2026/7/17 | info |
| 95715 | Siemens SIMATIC STEP 7 (TIA Portal) < 14 无引号服务路径本地权限提升 (SSA-701708) | Nessus | SCADA | 2016/12/12 | 2026/7/17 | medium |
| 117360 | Advantech WebAccess webvrpcs.exe 中存在路径遍历 RCE 漏洞 | Nessus | SCADA | 2018/9/10 | 2026/7/17 | critical |
| 124591 | Advantech WebAccess webvrpcs.exe 0x138bd IOCTL 中存在 RCE 漏洞 | Nessus | SCADA | 2019/5/3 | 2026/7/17 | critical |
| 23799 | Areva/Alstom 能源管理系统检测 | Nessus | SCADA | 2006/12/11 | 2026/7/17 | info |
| 64683 | Siemens SIMATIC RF-MANAGER KeyHelp.ocx 缓冲区溢出 | Nessus | SCADA | 2013/2/19 | 2026/7/17 | medium |
| 70292 | WellinTech KingView ActiveX 多种任意文件覆盖漏洞 | Nessus | SCADA | 2013/10/3 | 2026/7/17 | medium |
| 80910 | Honeywell OPOS Suite 堆栈缓冲区溢出 | Nessus | SCADA | 2015/1/22 | 2026/7/17 | high |
| 81701 | Advantech ADAMView 安装检测 | Nessus | SCADA | 2015/3/9 | 2026/7/17 | info |
| 90001 | PACTware 检测 | Nessus | SCADA | 2016/3/17 | 2026/7/17 | info |
| 23803 | National Instruments Lookout 检测 | Nessus | SCADA | 2006/12/11 | 2026/7/17 | info |
| 49694 | BACnet OPC Client < 1.0.25 缓冲区溢出 | Nessus | SCADA | 2010/9/24 | 2026/7/17 | high |
| 58448 | 7-Technologies AQUIS 检测 | Nessus | SCADA | 2012/3/23 | 2026/7/17 | info |
| 59500 | WellinTech KingOPCServer 检测 | Nessus | SCADA | 2012/6/14 | 2026/7/17 | info |
| 94329 | OMRON FINS UDP 协议检测 | Nessus | SCADA | 2016/10/27 | 2026/7/17 | info |
| 23805 | Siemens S7-SCL 开发工具检测 | Nessus | SCADA | 2006/12/11 | 2026/7/17 | info |
| 23807 | Siemens-Telegr ICCP 网关检测 | Nessus | SCADA | 2006/12/11 | 2026/7/17 | info |
| 117671 | Rockwell Automation RSLinx Classic <= 4.00.01 多个漏洞 | Nessus | SCADA | 2018/9/24 | 2026/7/27 | critical |
| 120947 | 3S CODESYS Runtime 3.x < 3.5.14.0 访问控制不足漏洞 | Nessus | SCADA | 2019/1/3 | 2026/7/27 | critical |
| 133216 | Siemens SIMATIC STEP 7 TIA Portal 中的本地特权提升漏洞 (SSA-629512) | Nessus | SCADA | 2020/1/24 | 2026/7/27 | high |
| 149971 | Schneider Electric C-Gate < 2.11.6 多个漏洞 | Nessus | SCADA | 2021/5/26 | 2026/7/27 | high |
| 76575 | Triangle MicroWorks SCADA Data Gateway < 3.3.729 心跳信息泄露 (Heartbleed) | Nessus | SCADA | 2014/7/7 | 2025/9/29 | high |
| 100463 | GE Multilin UR / URPlus / B95Plus 中继 Web 界面检测 | Nessus | SCADA | 2017/5/26 | 2026/3/23 | info |
| 106229 | AVEVA InduSoft Web Studio / InTouch Edge HMI TCP/IP 服务器检测 | Nessus | SCADA | 2018/1/22 | 2025/9/29 | info |
| 111139 | RedLion Crimson 协议检测 | Nessus | SCADA | 2018/7/17 | 2025/9/29 | info |
| 112162 | Siemens SIMATIC WinCC (TIA Portal) 10.x < 14 SP1 Upd6 多个漏洞 (SSA-979106) | Nessus | SCADA | 2018/8/28 | 2025/9/29 | high |