| 58449 | 7-Technologies AQUIS 不明路径 Subversion 任意 DLL 注入代码执行 | Nessus | SCADA | 2012/3/23 | 2026/4/8 | high |
| 58451 | 7-Technologies TERMIS 不明路径 Subversion 任意 DLL 注入代码执行 | Nessus | SCADA | 2012/3/23 | 2026/4/8 | high |
| 59374 | WellinTech KingView 检测 | Nessus | SCADA | 2012/6/5 | 2026/4/8 | info |
| 59375 | WellinTech KingView 6.53 < 2010-12-15 HistorySvr.exe TCP 请求远程溢出 | Nessus | SCADA | 2012/6/5 | 2026/4/8 | critical |
| 59377 | WellinTech KingView 6.53 < 2012-03-22 多种漏洞 | Nessus | SCADA | 2012/6/5 | 2026/4/8 | critical |
| 65656 | Honeywell 多种产品 HscRemoteDepoy.dll ActiveX 控件任意代码执行 | Nessus | SCADA | 2013/3/22 | 2026/4/8 | medium |
| 70591 | KEPServerEX 检测 | Nessus | SCADA | 2013/10/24 | 2026/4/8 | info |
| 84498 | Siemens SIMATIC ProSave 检测 | Nessus | SCADA | 2015/7/2 | 2026/4/8 | info |
| 88412 | iniNet SpiderControl SCADA Editor 检测 | Nessus | SCADA | 2016/1/27 | 2026/4/8 | info |
| 97667 | Siemens SIMATIC Logon 检测 | Nessus | SCADA | 2017/3/10 | 2026/4/8 | info |
| 122424 | CODESYS V3 运行时间服务检测 | Nessus | SCADA | 2019/2/26 | 2026/4/8 | info |
| 129292 | Advantech WebAccess webvprcs IOCTL 70603 堆栈溢出 | Nessus | SCADA | 2019/9/24 | 2026/4/8 | critical |
| 56993 | Advantech / BroadWin WebAccess Client“bwocxrun.ocx”多个远程漏洞 | Nessus | SCADA | 2011/12/2 | 2026/4/8 | high |
| 60084 | Advantech Studio ISSymbol ActiveX 控件多种缓冲区溢出漏洞 | Nessus | SCADA | 2012/7/20 | 2026/4/8 | high |
| 72708 | Mitsubishi Electric Automation MC-WorX 8.x ActiveX 控件远程代码执行 | Nessus | SCADA | 2014/2/26 | 2026/4/8 | high |
| 81789 | Siemens SIMATIC STEP 7 (TIA Portal) V13 检测 | Nessus | SCADA | 2015/3/12 | 2026/4/8 | info |
| 72556 | 3S CODESYS 2.x 开发系统检测(凭据检查) | Nessus | SCADA | 2014/2/18 | 2026/4/8 | info |
| 73641 | Advantech WebAccess 多种 BWOCXRUN.OCX ActiveX 漏洞 | Nessus | SCADA | 2014/4/14 | 2026/4/8 | high |
| 81577 | Siemens SIMATIC WinCC (TIA Portal) V13 检测 | Nessus | SCADA | 2015/3/1 | 2026/4/8 | info |
| 95716 | Siemens SIMATIC WinCC (TIA Portal) < 14 无引号服务路径本地权限提升 (SSA-701708) | Nessus | SCADA | 2016/12/12 | 2026/4/8 | medium |
| 131736 | CODESYS ENI 服务器 < 3.2.2.25 堆栈溢出(凭据检查) | Nessus | SCADA | 2019/12/6 | 2026/4/16 | critical |
| 134977 | 3S CODESYS Runtime 3.x < 3.5.14.20 中存在多个漏洞 | Nessus | SCADA | 2020/3/30 | 2026/4/16 | critical |
| 136182 | 3S CODESYS Runtime 3.x < 3.5.15.40 中存在多个漏洞 | Nessus | SCADA | 2020/4/30 | 2026/4/16 | critical |
| 137356 | Inductive Automation Ignition 8.x < 8.0.10 中存在多个漏洞 | Nessus | SCADA | 2020/6/11 | 2026/4/16 | high |
| 103533 | Trihedral VTScada 8.x < 11.2.02 中存在多个漏洞 | Nessus | SCADA | 2017/9/28 | 2025/7/14 | critical |
| 104101 | Schneider Electric InduSoft Web Studio < 8.0 SP2 Patch 1 不明远程命令执行 (LFSEC00000121) | Nessus | SCADA | 2017/10/23 | 2025/11/17 | critical |
| 111466 | AVEVA InduSoft Web Studio / InTouch Machine Edition 命令 81 mbstowcs() 中存在堆栈溢出 | Nessus | SCADA | 2018/7/31 | 2025/9/29 | critical |
| 149523 | OPC UA opc.tcp 检测 | Nessus | SCADA | 2021/5/17 | 2025/9/29 | info |
| 23814 | SISCO OSI 堆栈漏洞扫描远程 DoS | Nessus | SCADA | 2006/12/11 | 2025/7/14 | high |
| 23817 | Modbus/TCP Coil Access | Nessus | SCADA | 2006/12/11 | 2025/9/29 | medium |
| 25147 | LiveData 服务器多个远程漏洞 | Nessus | SCADA | 2007/5/3 | 2025/7/14 | critical |
| 50303 | Moxa Device Manager 网关检测 | Nessus | SCADA | 2010/10/22 | 2025/9/29 | info |
| 53543 | RealWin < 2.1.12 多种缓冲区溢出 | Nessus | SCADA | 2011/4/25 | 2025/7/14 | critical |
| 59373 | WellinTech KingView History Server 检测 | Nessus | SCADA | 2012/6/5 | 2025/7/14 | info |
| 62795 | CODESYS PLC 运行时服务检测 | Nessus | SCADA | 2012/11/2 | 2025/9/29 | info |
| 64297 | 不支持的 Schneider Electric Interactive Graphical SCADA System (IGSS) 版本 | Nessus | SCADA | 2013/1/30 | 2025/7/14 | critical |
| 70531 | Siemens SCALANCE X-200 Web 会话劫持 | Nessus | SCADA | 2013/10/21 | 2025/7/14 | high |
| 72557 | 3S CoDeSys Runtime Toolkit 空指针取消引用(凭据检查) | Nessus | SCADA | 2014/2/18 | 2025/7/14 | medium |
| 72558 | 3S CoDeSys Runtime Toolkit 空指针取消引用(无凭据检查) | Nessus | SCADA | 2014/2/18 | 2025/7/14 | medium |
| 73567 | BACnet 协议检测 | Nessus | SCADA | 2014/4/16 | 2025/9/29 | info |
| 81049 | StruxureWare SCADA Expert ClearSCADA 弱哈希算法 | Nessus | SCADA | 2015/1/28 | 2025/7/14 | medium |
| 81249 | MatrikonOPC Server for DNP3 < 1.2.3.1 消息处理远程 DoS | Nessus | SCADA | 2015/2/9 | 2025/9/29 | medium |
| 81700 | Advantech ADAMView 多种缓冲区溢出漏洞 | Nessus | SCADA | 2015/3/9 | 2025/9/29 | high |
| 82665 | WellinTech KingView < 6.53 (2012-10-09) 用户凭据未安全地执行哈希运算 | Nessus | SCADA | 2015/4/9 | 2025/9/29 | low |
| 83917 | WellinTech KingSCADA < 3.1.2.13-EN KAEClientManager 控制台远程认证凭据泄露 | Nessus | SCADA | 2015/6/1 | 2025/9/29 | medium |
| 86572 | 3S CODESYS Runtime Toolkit < 2.4.7.48 PLCWinNT DoS(凭据检查) | Nessus | SCADA | 2015/10/23 | 2025/9/29 | medium |
| 91345 | Allen-Bradley MicroLogix 1400 多个漏洞 | Nessus | SCADA | 2016/5/27 | 2025/9/29 | critical |
| 91346 | EtherNet/IP CIP EDS 元数据 | Nessus | SCADA | 2016/5/27 | 2025/9/29 | info |
| 91626 | Panasonic FPWIN Pro 5.x < 7.130 多种漏洞 | Nessus | SCADA | 2016/6/15 | 2025/9/29 | medium |
| 67142 | Tridium Niagara AX Web Server 检测 | Nessus | SCADA | 2013/7/3 | 2026/3/23 | info |