| 81591 | Siemens SIMATIC S7-1200 PLC 固件检测 | Nessus | SCADA | 2015/3/2 | 2025/7/14 | info |
| 83302 | Modbus/TCP Report Slave ID | Nessus | SCADA | 2015/5/10 | 2025/9/29 | medium |
| 83467 | 活动对象类的 EtherNet/IP CIP 列表 | Nessus | SCADA | 2015/5/14 | 2025/9/29 | info |
| 91283 | Moxa NPort Serial-to-Ethernet 服务器检测 | Nessus | SCADA | 2016/5/20 | 2025/7/14 | info |
| 91622 | Cogent DataHub < 6.4.3 OPC 客户端重新连接饱和远程 DoS | Nessus | SCADA | 2016/6/15 | 2025/7/14 | medium |
| 94329 | OMRON FINS UDP 协议检测 | Nessus | SCADA | 2016/10/27 | 2025/12/15 | info |
| 59528 | RuggedCom RuggedOS 基于 Web 的管理界面默认凭据 | Nessus | SCADA | 2012/6/15 | 2026/3/23 | critical |
| 70559 | ClearSCADA Web Server 远程拒绝服务 | Nessus | SCADA | 2013/10/15 | 2026/3/23 | high |
| 73644 | Advantech WebAccess 默认凭据检查 | Nessus | SCADA | 2014/4/14 | 2026/3/23 | high |
| 73645 | Advantech WebAccess Web 管理界面检测 | Nessus | SCADA | 2014/4/14 | 2026/3/23 | info |
| 81593 | Siemens SIMATIC S7-1200 PLC Web 服务器检测 | Nessus | SCADA | 2015/3/2 | 2026/3/23 | info |
| 70558 | ClearSCADA Web 服务器检测 | Nessus | SCADA | 2013/10/23 | 2026/3/23 | info |
| 88413 | iniNet SpiderControl PLC Editor Beckhoff 6.30.04 本地权限升级 | Nessus | SCADA | 2016/1/27 | 2026/3/23 | high |
| 23799 | Areva/Alstom 能源管理系统检测 | Nessus | SCADA | 2006/12/11 | 2026/5/13 | info |
| 23803 | National Instruments Lookout 检测 | Nessus | SCADA | 2006/12/11 | 2026/5/13 | info |
| 23805 | Siemens S7-SCL 开发工具检测 | Nessus | SCADA | 2006/12/11 | 2026/5/13 | info |
| 23807 | Siemens-Telegr ICCP 网关检测 | Nessus | SCADA | 2006/12/11 | 2026/5/13 | info |
| 58448 | 7-Technologies AQUIS 检测 | Nessus | SCADA | 2012/3/23 | 2026/5/13 | info |
| 59500 | WellinTech KingOPCServer 检测 | Nessus | SCADA | 2012/6/14 | 2026/5/13 | info |
| 59556 | Measuresoft ScadaPro 检测 | Nessus | SCADA | 2012/6/18 | 2026/5/13 | info |
| 81701 | Advantech ADAMView 安装检测 | Nessus | SCADA | 2015/3/9 | 2026/5/13 | info |
| 90001 | PACTware 检测 | Nessus | SCADA | 2016/3/17 | 2026/5/13 | info |
| 91625 | Panasonic Control FPWIN Pro 检测 | Nessus | SCADA | 2016/6/15 | 2026/5/13 | info |
| 23967 | ICONICS Dialog Wrapper Module ActiveX (DlgWrapper.dll) DoModal 函数溢出 | Nessus | SCADA | 2007/1/3 | 2026/5/13 | high |
| 59527 | 基于 Web 的 RuggedCom RuggedOS (ROS) 管理界面检测 | Nessus | SCADA | 2012/6/15 | 2026/3/23 | info |
| 89031 | 7-Technologies IGSS < 10.0.0 ODBC 缓冲区溢出 RCE | Nessus | SCADA | 2016/2/29 | 2025/7/14 | critical |
| 103048 | Advantech WebAccess < 8.2_20170817 中存在多个漏洞 | Nessus | SCADA | 2017/9/8 | 2026/3/23 | critical |
| 130430 | CODESYS Gateway V3 DoS | Nessus | SCADA | 2019/10/31 | 2025/9/29 | high |
| 133216 | Siemens SIMATIC STEP 7 TIA Portal 中的本地特权提升漏洞 (SSA-629512) | Nessus | SCADA | 2020/1/24 | 2026/4/16 | high |
| 117671 | Rockwell Automation RSLinx Classic <= 4.00.01 多个漏洞 | Nessus | SCADA | 2018/9/24 | 2026/4/16 | critical |
| 119265 | Rockwell Automation RSLinx Classic ENGINE.dll 堆栈缓冲区溢出 | Nessus | SCADA | 2018/11/28 | 2025/9/29 | critical |
| 64683 | Siemens SIMATIC RF-MANAGER KeyHelp.ocx 缓冲区溢出 | Nessus | SCADA | 2013/2/19 | 2026/5/13 | medium |
| 62796 | CoDeSys 认证绕过目录遍历 | Nessus | SCADA | 2012/11/2 | 2025/9/29 | critical |
| 77964 | Ecava IntegraXor < 4.2.4458 多种漏洞 | Nessus | SCADA | 2014/9/29 | 2025/9/29 | high |
| 80910 | Honeywell OPOS Suite 堆栈缓冲区溢出 | Nessus | SCADA | 2015/1/22 | 2026/5/13 | high |
| 81376 | Siemens SCALANCE X-200IRT < 5.2.0 中存在会话劫持 | Nessus | SCADA | 2015/2/16 | 2025/7/14 | medium |
| 81592 | Siemens SIMATIC S7-1200 PLC < 4.1 中存在开放重定向 | Nessus | SCADA | 2015/3/2 | 2025/7/14 | medium |
| 84263 | Schneider Electric InduSoft Web Studio < 7.1.3.4 多种信息泄漏 (SEVD-2015-054-01) | Nessus | SCADA | 2015/6/18 | 2026/3/23 | medium |
| 87891 | Janitza 多个 UMG 设备远程调试接口 RCE | Nessus | SCADA | 2016/1/13 | 2025/7/14 | high |
| 95715 | Siemens SIMATIC STEP 7 (TIA Portal) < 14 无引号服务路径本地权限提升 (SSA-701708) | Nessus | SCADA | 2016/12/12 | 2026/5/13 | medium |
| 73303 | Ecava IntegraXor < 4.1.4410 信息泄露 | Nessus | SCADA | 2014/4/2 | 2025/9/29 | medium |
| 53877 | Samsung Data Management Server < 1.4.3 verifyUser 方法 SQL 注入 | Nessus | SCADA | 2011/5/11 | 2026/3/23 | high |
| 85600 | Advantech WebAccess 7.2 < 7.2-2014.07.30 多个 ActiveX RCE | Nessus | SCADA | 2015/8/24 | 2026/3/23 | medium |
| 90002 | PACTware 4.1 SP3 (4.1.0.42) 处理文件处理错误时发生 DoS | Nessus | SCADA | 2016/3/17 | 2025/9/29 | medium |
| 151191 | Johnson Controls exacqVision Web Service 信息泄露 (JCI-PSA-2021-03) | Nessus | SCADA | 2021/6/30 | 2026/3/23 | high |
| 100299 | Siemens SIMATIC WinCC (TIA Portal) 13 < 13 SP2 / 14 < 14 SP1 多个 DoS | Nessus | SCADA | 2017/5/19 | 2025/9/29 | medium |
| 149971 | Schneider Electric C-Gate < 2.11.6 多个漏洞 | Nessus | SCADA | 2021/5/26 | 2026/4/16 | high |
| 49694 | BACnet OPC Client < 1.0.25 缓冲区溢出 | Nessus | SCADA | 2010/9/24 | 2026/5/13 | high |
| 53573 | Modbus/TCP Master OPC Server MODBUS 协议响应数据包远程溢出 | Nessus | SCADA | 2011/4/27 | 2025/7/14 | high |
| 55026 | Ecava IntegraXor 路径 Subversion 任意 DLL 注入代码执行 | Nessus | SCADA | 2011/6/9 | 2025/7/14 | high |