501208 | Schneider Electric Modicon Use of Hard-coded Credentials (CVE-2019-6859) | Tenable OT Security | Tenable.ot | 2023/6/29 | 2023/8/22 | high |
500240 | Schneider Electric Modicon Cleartext Transmission of Sensitive Information (CVE-2019-6846) | Tenable OT Security | Tenable.ot | 2022/2/7 | 2024/1/24 | medium |
500295 | Schneider Electric Modicon Improper Handling of Exceptional Conditions (CVE-2019-6844) | Tenable OT Security | Tenable.ot | 2022/2/7 | 2024/1/24 | medium |
500052 | Schneider Electric Modicon Improper Handling of Exceptional Conditions (CVE-2019-6848) | Tenable OT Security | Tenable.ot | 2022/2/7 | 2024/7/4 | high |
500062 | Schneider Electric Modicon Improper Handling of Exceptional Conditions (CVE-2019-6828) | Tenable OT Security | Tenable.ot | 2022/2/7 | 2024/1/24 | high |
500193 | Schneider Electric Modicon Improper Handling of Exceptional Conditions (CVE-2019-6843) | Tenable OT Security | Tenable.ot | 2022/2/7 | 2024/1/24 | medium |
500199 | Schneider Electric Modicon Improper Handling of Exceptional Conditions (CVE-2019-6841) | Tenable OT Security | Tenable.ot | 2022/2/7 | 2024/1/24 | medium |
764317 | Schneider Electric Altivar ATV 600 ATV630U07M3 Variable Speed Drive | Nessus Network Monitor | SCADA | 2019/5/31 | 2019/9/30 | info |
764320 | Schneider Electric Altivar ATV 600 ATV630U30M3 Variable Speed Drive | Nessus Network Monitor | SCADA | 2019/5/31 | 2019/9/30 | info |
764325 | Schneider Electric Altivar ATV 600 ATV630D15M3 Variable Speed Drive | Nessus Network Monitor | SCADA | 2019/5/31 | 2019/9/30 | info |
764328 | Schneider Electric Altivar ATV 600 ATV630D30M3 Variable Speed Drive | Nessus Network Monitor | SCADA | 2019/5/31 | 2019/9/30 | info |
720244 | Schneider Electric Modicon Multiple Controllers Unauthorized Password Delete | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | critical |
720245 | Schneider Electric Modicon Multiple Controllers Cross-Site Scripting | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
720248 | Schneider Electric Modicon Multiple Controllers HTTP Response Splitting | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
502835 | Schneider Electric EcoStruxure Control Expert, EcoStruxure Process Expert, and Modicon M340, M580 and M580 Safety PLCs Improper Enforcement of Message Integrity During Transmission in a Communication Channel (CVE-2023-6408) | Tenable OT Security | Tenable.ot | 2025/2/5 | 2025/2/25 | high |
500875 | Schneider Electric Modicon Allocation of Resources Without Limits or Throttling (CVE-2018-7821) | Tenable OT Security | Tenable.ot | 2023/3/1 | 2024/1/24 | high |
500879 | Schneider Electric EcoStruxure Control Expert, Process Expert, Modicon M340, M580 and M580 CPU Authentication Bypass By Capture-Replay (CVE-2022-45789) | Tenable OT Security | Tenable.ot | 2023/3/9 | 2024/9/4 | critical |
500918 | Schneider Electric Wiser Smart Incorrect Resource Transfer Between Spheres (CVE-2022-30236) | Tenable OT Security | Tenable.ot | 2023/3/29 | 2023/8/22 | high |
501144 | Schneider Electric Modicon Improper Check for Unusual or Exceptional Conditions (CVE-2023-25620) | Tenable OT Security | Tenable.ot | 2023/5/16 | 2023/8/22 | medium |
501195 | Schneider Electric Quantum Ethernet Network Module Improper Check for Unusual or Exceptional Conditions (CVE-2020-7477) | Tenable OT Security | Tenable.ot | 2023/6/29 | 2023/8/22 | high |
501197 | Schneider Electric Modicon Improper Check for Unusual or Exceptional Conditions (CVE-2020-7549) | Tenable OT Security | Tenable.ot | 2023/6/29 | 2023/8/22 | medium |
501202 | Schneider Electric Modicon Exposure of Sensitive Information to an Unauthorized Actor (CVE-2019-6852) | Tenable OT Security | Tenable.ot | 2023/6/29 | 2023/8/22 | high |
501213 | Schneider Electric Modicon Exposure of Sensitive Information to an Unauthorized Actor (CVE-2021-22785) | Tenable OT Security | Tenable.ot | 2023/6/29 | 2023/8/22 | high |
500124 | Schneider Electric Modicon Improper Check for Unusual or Exceptional Conditions (CVE-2018-7856) | Tenable OT Security | Tenable.ot | 2022/2/7 | 2024/1/24 | high |
500243 | Schneider Electric Modicon Improper Check for Unusual or Exceptional Conditions (CVE-2018-7854) | Tenable OT Security | Tenable.ot | 2022/2/7 | 2024/1/24 | high |
500244 | Schneider Electric Modicon Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2018-7851) | Tenable OT Security | Tenable.ot | 2022/2/7 | 2024/1/24 | medium |
500293 | Schneider Electric Modicon Exposure of Sensitive Information to an Unauthorized Actor (CVE-2019-6849) | Tenable OT Security | Tenable.ot | 2022/2/7 | 2024/7/4 | high |
720246 | Schneider Electric Modicon Multiple Controllers Unverified Password Change | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | critical |
500689 | Schneider Electric Modicon Insufficient Verification of Data Authenticity (CVE-2022-34763) | Tenable OT Security | Tenable.ot | 2022/7/27 | 2023/10/17 | high |
500071 | Schneider Electric Modicon Missing Authentication for Critical Function (CVE-2019-6808) | Tenable OT Security | Tenable.ot | 2022/2/7 | 2024/1/24 | critical |
500684 | Schneider Electric Modicon Exposure of Resource to Wrong Sphere (CVE-2022-34765) | Tenable OT Security | Tenable.ot | 2022/7/21 | 2023/10/17 | medium |
500907 | Schneider Electric Wiser Smart Use of Hard-coded Credentials (CVE-2022-30234) | Tenable OT Security | Tenable.ot | 2023/3/29 | 2023/8/22 | critical |
500635 | Schneider Electric Plaintext Storage of a Password in embedded Rockwell Automation ISaGRAF5 Runtime (CVE-2020-25184) | Tenable OT Security | Tenable.ot | 2022/4/28 | 2024/9/4 | medium |
500639 | Schneider Electric Cleartext Transmission of Sensitive Information in embedded Rockwell Automation ISaGRAF5 Runtime (CVE-2020-25178) | Tenable OT Security | Tenable.ot | 2022/4/28 | 2024/9/4 | high |
500649 | Schneider Electric Uncontrolled Search Path Element in embedded Rockwell Automation ISaGRAF5 Runtime (CVE-2020-25182) | Tenable OT Security | Tenable.ot | 2022/4/28 | 2024/9/4 | medium |
500700 | Schneider Electric Modicon Weak Password Recovery Mechanism for Forgotten Password (CVE-2022-37300) | Tenable OT Security | Tenable.ot | 2022/9/15 | 2023/10/11 | critical |
501143 | Schneider Electric Modicon Improper Check for Unusual or Exceptional Conditions (CVE-2023-25619) | Tenable OT Security | Tenable.ot | 2023/5/16 | 2023/8/22 | high |
501217 | Schneider Electric Modicon Improper Check for Unusual or Exceptional Conditions (CVE-2020-7539) | Tenable OT Security | Tenable.ot | 2023/6/29 | 2024/4/11 | high |
500276 | Schneider Electric Modicon Weak Password Recovery Mechanism for Forgotten Password (CVE-2018-7811) | Tenable OT Security | Tenable.ot | 2022/2/7 | 2023/11/30 | critical |
500299 | Schneider Electric Modicon Exposure of Sensitive Information to an Unauthorized Actor (CVE-2018-7812) | Tenable OT Security | Tenable.ot | 2022/2/7 | 2023/11/30 | high |
500496 | Schneider Electric Modicon Improper Check for Unusual or Exceptional Conditions (CVE-2020-7543) | Tenable OT Security | Tenable.ot | 2022/2/7 | 2024/4/11 | high |
500182 | Schneider Electric Modicon Exposure of Sensitive Information to an Unauthorized Actor (CVE-2019-6851) | Tenable OT Security | Tenable.ot | 2022/2/7 | 2024/1/24 | high |
720009 | Schneider Electric Quantum Ethernet Module Multiple Versions Hardcoded Passwords | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | critical |
500919 | Schneider Electric Wiser Smart Missing Encryption of Sensitive Data (CVE-2022-30237) | Tenable OT Security | Tenable.ot | 2023/3/29 | 2023/8/22 | high |
500125 | Schneider Electric Modicon Exposure of Resource to Wrong Sphere (CVE-2018-7846) | Tenable OT Security | Tenable.ot | 2022/2/7 | 2024/1/24 | critical |
502368 | Schneider Electric Modicon M340, BMXNOE0100 and BMXNOE0110 Files or Directories Accessible to External Parties (CVE-2024-5056) | Tenable OT Security | Tenable.ot | 2024/8/26 | 2024/12/19 | medium |
500573 | Schneider Electric Modicon Improper Check for Unusual or Exceptional Conditions (CVE-2020-7542) | Tenable OT Security | Tenable.ot | 2022/2/7 | 2024/4/11 | high |
500647 | Schneider Electric Use of Hard-Coded Cryptographic Key in embedded Rockwell Automation ISaGRAF5 Runtime (CVE-2020-25180) | Tenable OT Security | Tenable.ot | 2022/4/28 | 2024/9/4 | medium |
500671 | Schneider Electric PowerLogic Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2021-22713) | Tenable OT Security | Tenable.ot | 2022/7/21 | 2023/10/17 | high |
500912 | Schneider Electric Wiser Smart Improper Restriction of Excessive Authentication Attempts (CVE-2022-30235) | Tenable OT Security | Tenable.ot | 2023/3/29 | 2023/8/22 | critical |