| 67142 | Tridium Niagara AX Web Server 检测 | Nessus | SCADA | 2013/7/3 | 2026/3/23 | info |
| 73643 | Advantech WebAccess < 7.2-2014.06.06 多种漏洞 | Nessus | SCADA | 2014/4/14 | 2026/3/23 | high |
| 83264 | Siemens SCALANCE S612 Firewall 检测 | Nessus | SCADA | 2015/5/6 | 2026/3/23 | info |
| 83951 | Inductive Automation Ignition 检测 | Nessus | SCADA | 2015/6/2 | 2026/3/23 | info |
| 84566 | Rockwell Automation MicroLogix 1100 PLC 默认凭据 | Nessus | SCADA | 2015/7/7 | 2026/3/23 | high |
| 85403 | Schneider Electric InduSoft Web Studio < 7.1.3.5 本地明文密码信息泄露 (SEVD-2015-100-01) | Nessus | SCADA | 2015/8/14 | 2026/3/23 | low |
| 91385 | MicroLogix 1400 PLC Web 服务器请求处理 RCE | Nessus | SCADA | 2016/5/31 | 2026/3/23 | critical |
| 131402 | Siemens SINEMA 远程连接服务器多个漏洞 (SSA-884497) | Nessus | SCADA | 2019/12/2 | 2026/3/23 | critical |
| 72201 | StruxureWare SCADA Expert ClearSCADA < 2013 R2 远程 DoS | Nessus | SCADA | 2014/1/29 | 2026/3/23 | medium |
| 84262 | Schneider Electric InduSoft Web Studio 检测 | Nessus | SCADA | 2015/6/18 | 2026/3/23 | info |
| 84567 | Rockwell Automation MicroLogix 1100 PLC < 系列 B FRN 13.0 多种漏洞 | Nessus | SCADA | 2015/7/7 | 2026/3/23 | critical |
| 84569 | Rockwell Automation MicroLogix 1100 PLC Web 服务器检测 | Nessus | SCADA | 2015/7/7 | 2026/3/23 | info |
| 87126 | Emerson SM-Ethernet Web 接口检测 | Nessus | SCADA | 2015/12/1 | 2026/3/23 | info |
| 122186 | AVEVA InduSoft Web Studio / InTouch Edge HMI 命令 66 中存在 RCE 漏洞 | Nessus | SCADA | 2019/2/14 | 2025/9/29 | critical |
| 33201 | CitectSCADA ODBC 服务器远程缓冲区溢出 | Nessus | SCADA | 2008/6/18 | 2026/4/8 | high |
| 124329 | Advantech WebAccess webvrpcs.exe 任意文件下载 | Nessus | SCADA | 2019/4/26 | 2026/4/8 | high |
| 126469 | Advantech WebAccess webvprcs IOCTL 10012 堆栈溢出 | Nessus | SCADA | 2019/7/4 | 2026/4/8 | critical |
| 23800 | 用于 Modbus 检测的 Matrikon OPC Server | Nessus | SCADA | 2006/12/11 | 2026/4/8 | info |
| 23801 | Matrikon OPC Explorer 检测 | Nessus | SCADA | 2006/12/11 | 2026/4/8 | info |
| 23804 | Siemens SIMATIC PDM 检测 | Nessus | SCADA | 2006/12/11 | 2026/4/8 | info |
| 26066 | 自动化解决方案 Modbus Slave MiniHMI.exe ActiveX Modbus/TCP 诊断功能 任意代码执行 | Nessus | SCADA | 2007/9/19 | 2026/4/8 | high |
| 52961 | 7-Technologies / Schneider-Electric IGSS 检测 | Nessus | SCADA | 2011/3/24 | 2026/4/8 | info |
| 59376 | WellinTech KingView 6.53 < 2011-11-20 HistoryServer.exe nettransdll.dll 模块操作码 3 数据包解析远程溢出 | Nessus | SCADA | 2012/6/5 | 2026/4/8 | critical |
| 64682 | Siemens SIMATIC RF-MANAGER 检测 | Nessus | SCADA | 2013/2/19 | 2026/4/8 | info |
| 65602 | Schneider Electric Accutech Manager 检测 | Nessus | SCADA | 2013/3/18 | 2026/4/8 | info |
| 72702 | StruxureWare SCADA Expert ClearSCADA 检测 | Nessus | SCADA | 2014/2/26 | 2026/4/8 | info |
| 72703 | StruxureWare SCADA Expert ClearSCADA 不明漏洞 | Nessus | SCADA | 2014/2/26 | 2026/4/8 | medium |
| 76573 | Triangle MicroWorks SCADA Data Gateway 检测(凭据检查) | Nessus | SCADA | 2014/7/17 | 2026/4/8 | info |
| 83522 | Rockwell Automation RSLinx Classic 检测 | Nessus | SCADA | 2015/5/18 | 2026/4/8 | info |
| 97666 | Siemens SIMATIC Logon 身份验证绕过 | Nessus | SCADA | 2017/3/10 | 2026/4/8 | critical |
| 23802 | 用于 ControlLogix 检测的 Matrikon OPC Server | Nessus | SCADA | 2006/12/11 | 2026/4/8 | info |
| 23825 | Modicon PLC Modbus 从属模式 SNMP 请求 Modbus 模式远程泄露 | Nessus | SCADA | 2006/12/11 | 2026/4/8 | medium |
| 83187 | Schneider Electric OPC Factory Server (OFS) < 3.5 SP1 ActiveX 对象多个缓冲区溢出 DoS | Nessus | SCADA | 2015/5/1 | 2026/4/8 | high |
| 81107 | Schneider Electric 多种产品缓冲区溢出 | Nessus | SCADA | 2015/1/30 | 2026/4/8 | high |
| 85411 | Advantech WebAccess < 7.2-2013.11.14 多种漏洞 | Nessus | SCADA | 2015/8/17 | 2026/3/23 | high |
| 125392 | Siemens SIMATIC WinCC (TIA Portal) < 15 Update 4 多种漏洞 (SSA-233109) | Nessus | SCADA | 2019/5/24 | 2026/4/16 | high |
| 127057 | Siemens SIMATIC WinCC (TIA Portal) 代码上传漏洞 (SSA-121293) | Nessus | SCADA | 2019/7/26 | 2026/4/16 | high |
| 102991 | Siemens SIMATIC WinCC (TIA Portal) < 14 SP1 XXE 漏洞 | Nessus | SCADA | 2017/9/7 | 2025/9/29 | high |
| 106229 | AVEVA InduSoft Web Studio / InTouch Edge HMI TCP/IP 服务器检测 | Nessus | SCADA | 2018/1/22 | 2025/9/29 | info |
| 111139 | RedLion Crimson 协议检测 | Nessus | SCADA | 2018/7/17 | 2025/9/29 | info |
| 112162 | Siemens SIMATIC WinCC (TIA Portal) 10.x < 14 SP1 Upd6 多个漏洞 (SSA-979106) | Nessus | SCADA | 2018/8/28 | 2025/9/29 | high |
| 118576 | AVEVA InduSoft Web Studio / InTouch Edge HMI UniSoft.dll wcscpy() 中存在堆栈溢出 | Nessus | SCADA | 2018/10/31 | 2025/9/29 | critical |
| 118711 | DNP3 设备检测属性 | Nessus | SCADA | 2018/11/2 | 2025/9/29 | info |
| 150962 | CodeMeter Runtime 缓冲区过度读取 (WIBU-210423-01) | Nessus | SCADA | 2021/6/23 | 2025/9/29 | critical |
| 23810 | DNP3 分站非请求消息传递支持 | Nessus | SCADA | 2006/12/11 | 2025/9/29 | medium |
| 23811 | ICCP/COTP (ISO 8073) 协议检测 | Nessus | SCADA | 2006/12/11 | 2025/9/29 | high |
| 23821 | Schneider Electric FTP 服务器默认凭据 | Nessus | SCADA | 2006/12/11 | 2025/7/14 | critical |
| 23830 | OPC 历史数据访问 (HDA) 服务器检测 | Nessus | SCADA | 2006/12/11 | 2025/7/14 | info |
| 24725 | SISCO OSI 堆栈畸形数据包远程 DoS | Nessus | SCADA | 2007/2/27 | 2025/7/14 | medium |
| 52993 | Movicon < 11.2 Build 1084 多种漏洞 | Nessus | SCADA | 2011/3/25 | 2025/7/14 | high |