23816 | Tamarack IEC 61850 服务器检测 | Nessus | SCADA | 2006/12/11 | 2024/5/20 | info |
23820 | Modicon PLC 嵌入式 HTTP 服务器检测 | Nessus | SCADA | 2006/12/11 | 2024/5/20 | medium |
59502 | WellinTech KingSCADA 3.1 < 2012-04-16 user.db Base-64 编码本地凭据泄露 | Nessus | SCADA | 2012/6/14 | 2024/5/20 | high |
70592 | KEPServerEX < 5.12.140.0 拒绝服务 | Nessus | SCADA | 2013/10/24 | 2024/5/20 | high |
73516 | RuggedCom RuggedOS SNMP 协议不明 DoS | Nessus | SCADA | 2014/4/15 | 2024/5/20 | high |
80910 | Honeywell OPOS Suite 堆栈缓冲区溢出 | Nessus | SCADA | 2015/1/22 | 2024/5/20 | high |
81376 | Siemens SCALANCE X-200IRT < 5.2.0 中存在会话劫持 | Nessus | SCADA | 2015/2/16 | 2024/5/20 | medium |
83302 | Modbus/TCP Report Slave ID | Nessus | SCADA | 2015/5/10 | 2024/5/20 | medium |
83917 | WellinTech KingSCADA < 3.1.2.13-EN KAEClientManager 控制台远程认证凭据泄露 | Nessus | SCADA | 2015/6/1 | 2024/5/20 | medium |
84499 | Siemens SIMATIC ProSave < 1300.100.2201.15 不受信任的路径任意代码执行 (SSA-451236) | Nessus | SCADA | 2015/7/2 | 2024/5/20 | medium |
88412 | iniNet SpiderControl SCADA Editor 检测 | Nessus | SCADA | 2016/1/27 | 2024/5/20 | info |
90599 | Rockwell Automation MicroLogix 1400 PLC 默认凭据 | Nessus | SCADA | 2016/4/20 | 2024/5/20 | critical |
91624 | Cogent DataHub < 6.4.7 传入的 DDE 连接处理远程 DoS | Nessus | SCADA | 2016/6/15 | 2024/5/20 | medium |
99168 | Siemens S7 协议支持检测 | Nessus | SCADA | 2017/4/3 | 2024/5/20 | info |
149308 | CodeMeter Runtime 检测 | Nessus | SCADA | 2021/5/6 | 2024/5/20 | info |
59500 | WellinTech KingOPCServer 检测 | Nessus | SCADA | 2012/6/14 | 2024/5/20 | info |
65193 | CoDeSys Gateway 服务检测 | Nessus | SCADA | 2013/3/11 | 2024/5/20 | info |
70415 | ProSoft RadioLinx ControlScape 安装检测 | Nessus | SCADA | 2013/10/14 | 2024/5/20 | info |
70558 | ClearSCADA Web 服务器检测 | Nessus | SCADA | 2013/10/23 | 2024/5/20 | info |
72556 | 3S CODESYS 2.x 开发系统检测(凭据检查) | Nessus | SCADA | 2014/2/18 | 2024/5/20 | info |
72557 | 3S CoDeSys Runtime Toolkit 空指针取消引用(凭据检查) | Nessus | SCADA | 2014/2/18 | 2024/5/20 | medium |
73642 | Advantech WebAccess 存储的跨站脚本 | Nessus | SCADA | 2014/4/14 | 2024/5/20 | low |
76573 | Triangle MicroWorks SCADA Data Gateway 检测(凭据检查) | Nessus | SCADA | 2014/7/17 | 2024/5/20 | info |
81577 | Siemens SIMATIC WinCC (TIA Portal) V13 检测 | Nessus | SCADA | 2015/3/1 | 2024/5/20 | info |
81591 | Siemens SIMATIC S7-1200 PLC 固件检测 | Nessus | SCADA | 2015/3/2 | 2024/5/20 | info |
91622 | Cogent DataHub < 6.4.3 OPC 客户端重新连接饱和远程 DoS | Nessus | SCADA | 2016/6/15 | 2024/5/20 | medium |
91625 | Panasonic Control FPWIN Pro 检测 | Nessus | SCADA | 2016/6/15 | 2024/5/20 | info |
100463 | GE Multilin UR / URPlus / B95Plus 中继 Web 界面检测 | Nessus | SCADA | 2017/5/26 | 2024/5/20 | info |
122186 | AVEVA InduSoft Web Studio / InTouch Edge HMI 命令 66 中存在 RCE 漏洞 | Nessus | SCADA | 2019/2/14 | 2024/5/20 | critical |
130430 | CODESYS Gateway V3 DoS | Nessus | SCADA | 2019/10/31 | 2024/5/20 | high |
88839 | Advantech WebAccess openWidget 脚本路径遍历远程文件泄露 | Nessus | SCADA | 2016/2/18 | 2024/5/20 | high |
63428 | Siemens Automation License Manager 多种漏洞 | Nessus | SCADA | 2013/1/9 | 2024/5/20 | high |
59376 | WellinTech KingView 6.53 < 2011-11-20 HistoryServer.exe nettransdll.dll 模块操作码 3 数据包解析远程溢出 | Nessus | SCADA | 2012/6/5 | 2024/5/20 | critical |
52051 | Moxa Device Manager Tool MDM2_Gateway 响应远程溢出 | Nessus | SCADA | 2011/2/21 | 2024/5/20 | high |
62032 | Sielco Sistemi Winlog < 2.07.17 多种漏洞 | Nessus | SCADA | 2012/9/10 | 2024/5/20 | high |
62965 | IOServer XML 服务器 URI 目录遍历任意文件访问 | Nessus | SCADA | 2012/11/19 | 2024/5/20 | medium |
150962 | CodeMeter Runtime 缓冲区过度读取 (WIBU-210423-01) | Nessus | SCADA | 2021/6/23 | 2024/5/20 | critical |
77375 | Honeywell FALCON XL Web 控制器多种漏洞 | Nessus | SCADA | 2014/8/25 | 2024/5/20 | high |
104101 | Schneider Electric InduSoft Web Studio < 8.0 SP2 Patch 1 不明远程命令执行 (LFSEC00000121) | Nessus | SCADA | 2017/10/23 | 2018/11/15 | critical |
23805 | Siemens S7-SCL 开发工具检测 | Nessus | SCADA | 2006/12/11 | 2024/5/20 | info |
23806 | Telvent OASys 系统检测 | Nessus | SCADA | 2006/12/11 | 2024/5/20 | info |
77376 | CODESYS WAGO WebVisu 检测 | Nessus | SCADA | 2014/8/25 | 2014/8/25 | info |
117361 | Advantech WebAccess/SCADA Network Service 检测 | Nessus | SCADA | 2018/9/10 | 2024/5/20 | info |
59527 | 基于 Web 的 RuggedCom RuggedOS (ROS) 管理界面检测 | Nessus | SCADA | 2012/6/15 | 2024/5/20 | info |
59558 | Measuresoft ScadaPro < 4.0.1.0 service.exe 多种漏洞(凭据检查) | Nessus | SCADA | 2012/6/18 | 2024/5/20 | critical |
57600 | Modicon Quantum TFTP 任意文件上传 | Nessus | SCADA | 2012/1/19 | 2024/5/20 | high |
83467 | 活动对象类的 EtherNet/IP CIP 列表 | Nessus | SCADA | 2015/5/14 | 2024/5/20 | info |
87124 | Emerson SM-Ethernet FTP 服务器默认凭据 | Nessus | SCADA | 2015/12/1 | 2024/5/20 | critical |
120947 | 3S CODESYS Runtime 3.x < 3.5.14.0 访问控制不足漏洞 | Nessus | SCADA | 2019/1/3 | 2024/6/13 | critical |
125392 | Siemens SIMATIC WinCC (TIA Portal) < 15 Update 4 多种漏洞 (SSA-233109) | Nessus | SCADA | 2019/5/24 | 2024/6/13 | high |