| 183240 | LG LED Assistant Detection | Nessus | SCADA | 2023/10/17 | 2026/3/23 | info |
| 192106 | Milesight MilesightVPN Detection | Nessus | SCADA | 2024/3/14 | 2026/3/23 | info |
| 201195 | Siemens Automation License Manager Remote Detection | Nessus | SCADA | 2024/7/1 | 2025/9/29 | info |
| 205316 | Johnson Controls ExacqVision Web Server Inadequate Encryption Strength (JCI-PSA-2024-14) | Nessus | SCADA | 2024/8/9 | 2024/8/26 | high |
| 205658 | Schneider Electric Accutech Manager Buffer Overflow | Nessus | SCADA | 2024/8/16 | 2025/7/14 | high |
| 207349 | Schneider Electric Accutech Manager Server Detection | Nessus | SCADA | 2024/9/17 | 2025/9/29 | info |
| 207520 | Rockwell FactoryTalk Batch View < 3.00 Authentication Bypass | Nessus | SCADA | 2024/9/20 | 2025/1/30 | critical |
| 216263 | Siemens SIMATIC TIA Portal Session Expiration (SSA-342348) | Nessus | SCADA | 2025/2/14 | 2026/4/16 | high |
| 234854 | Rockwell Automation FactoryTalk Updater Authentication Bypass (CVE-2024-10943 | Nessus | SCADA | 2025/4/25 | 2026/3/23 | critical |
| 235084 | GMOD Apollo Detection | Nessus | SCADA | 2025/5/2 | 2026/3/23 | info |
| 23816 | Tamarack IEC 61850 Server Detection | Nessus | SCADA | 2006/12/11 | 2025/7/14 | info |
| 23820 | Modicon PLC Embedded HTTP Server Detection | Nessus | SCADA | 2006/12/11 | 2026/3/23 | medium |
| 23822 | Modicon Quantum HTTP Server Default Credentials | Nessus | SCADA | 2006/12/11 | 2026/3/23 | high |
| 23823 | Modicon PLC CPU Type SNMP Request Model Type Remote Disclosure | Nessus | SCADA | 2006/12/11 | 2026/4/8 | medium |
| 23824 | Modicon PLC IO Scan Status SNMP Request Scan Status Remote Disclosure | Nessus | SCADA | 2006/12/11 | 2026/4/8 | medium |
| 241649 | mySCADA PRO Manager Missing Authentication (CVE-2025-24865) | Nessus | SCADA | 2025/7/9 | 2026/3/23 | critical |
| 258072 | Siemens TeleControl Server Basic Database Service Detection | Nessus | SCADA | 2025/8/28 | 2025/9/29 | info |
| 265964 | Siemens User Management Component Out-of-bounds Read DoS (CVE-2025-40797) | Nessus | SCADA | 2025/9/26 | 2025/9/29 | high |
| 304405 | Delta Electronics COMMGR Detection | Nessus | SCADA | 2026/3/31 | 2026/3/31 | info |
| 50687 | RealWin < 2.1.10 Multiple Packet Type Processing Overflows | Nessus | SCADA | 2010/11/23 | 2025/7/14 | critical |
| 52962 | IGSS Data Server Directory Traversal Arbitrary File Access | Nessus | SCADA | 2011/3/24 | 2025/9/29 | medium |
| 52994 | Movicon TcpUploadServer Detection | Nessus | SCADA | 2011/3/25 | 2025/9/29 | info |
| 54291 | 7-Technologies IGSS < 9.0.0.11129 Multiple DoS Vulnerabilities | Nessus | SCADA | 2011/5/16 | 2025/7/14 | medium |
| 54645 | 7-Technologies IGSS < 9.0.0.11143 ODBC Remote Memory Corruption | Nessus | SCADA | 2011/5/25 | 2025/7/14 | critical |
| 59559 | Measuresoft ScadaPro Path Subversion Arbitrary DLL Injection Code Execution | Nessus | SCADA | 2012/6/18 | 2025/7/14 | high |
| 164696 | Keysight Technologies Sensor Management Server addLicenseFile Path Traversal (CVE-2022-38129) | Nessus | SCADA | 2022/9/6 | 2026/3/23 | critical |
| 155947 | CODESYS V3 Web Server Heap-based Buffer Overflow (CVE-2021-33485) | Nessus | SCADA | 2021/12/8 | 2026/3/23 | critical |
| 82269 | Honeywell XL Web Controller FTP Directory Traversal | Nessus | SCADA | 2015/3/26 | 2025/7/14 | critical |
| 85543 | Advantech WebAccess < 7.0-2011.08.27 Multiple ActiveX RCE | Nessus | SCADA | 2015/8/19 | 2026/3/23 | medium |
| 87125 | Emerson SM-Ethernet Web Interface Default Credentials | Nessus | SCADA | 2015/12/1 | 2026/3/23 | high |
| 87208 | 7-Technologies / Schneider-Electric IGSS Data Collector Detection | Nessus | SCADA | 2015/12/4 | 2025/9/29 | info |
| 88414 | iniNet SpiderControl PLC Editor Simatic 6.30.04 Local Privilege Escalation | Nessus | SCADA | 2016/1/27 | 2026/3/23 | high |
| 88416 | iniNet SpiderControl SCADA Web Server 2.02 Local Privilege Escalation | Nessus | SCADA | 2016/1/27 | 2026/3/23 | high |
| 89029 | 7-Technologies / Schneider-Electric IGSS ODBC Service Detection | Nessus | SCADA | 2016/2/29 | 2025/9/29 | info |
| 90599 | Rockwell Automation MicroLogix 1400 PLC Default Credentials | Nessus | SCADA | 2016/4/20 | 2026/3/23 | critical |
| 91623 | Cogent DataHub < 6.4.5Beta OPC Connection Failure DoS | Nessus | SCADA | 2016/6/15 | 2025/7/14 | medium |
| 96875 | Advantech WebAccess Authentication Bypass | Nessus | SCADA | 2017/1/30 | 2026/3/23 | critical |
| 63430 | Siemens Automation License Manager CVE-2012-4691 Denial of Service | Nessus | SCADA | 2013/1/9 | 2025/7/14 | low |
| 64487 | RuggedCom RuggedOS < 3.12.1 Web UI Multiple Security Vulnerabilities | Nessus | SCADA | 2013/2/6 | 2026/3/23 | critical |
| 65193 | CoDeSys Gateway Service Detection | Nessus | SCADA | 2013/3/11 | 2025/9/29 | info |
| 66805 | CoDeSys Gateway Service < 2.3.9.28 Use-After-Free | Nessus | SCADA | 2013/6/5 | 2025/7/14 | critical |
| 70530 | Siemens SCALANCE X-200 Authentication Bypass | Nessus | SCADA | 2013/10/21 | 2025/7/14 | critical |
| 77374 | Honeywell Excel (XL) Web Controller Detection | Nessus | SCADA | 2014/8/25 | 2025/7/14 | info |
| 191096 | Rockwell FactoryTalk Services Platform < 2.74 Privilege Escalation | Nessus | SCADA | 2024/2/28 | 2024/12/16 | high |
| 73642 | Advantech WebAccess Stored Cross-Site Scripting | Nessus | SCADA | 2014/4/14 | 2026/3/23 | low |
| 81545 | Siemens SIMATIC STEP 7 (TIA Portal) < 1300.100.2501.1 Multiple Vulnerabilities (SSA-315836) | Nessus | SCADA | 2015/2/26 | 2025/9/29 | medium |
| 125312 | Rockwell Automation MicroLogix 1100/1400 and CompactLogix 5370 Controllers Open Redirection Vulnerability | Nessus | SCADA | 2019/5/21 | 2026/3/23 | medium |
| 24872 | Takebishi Electric DeviceXPlorer OPC Server Multiple Vulnerabilities | Nessus | SCADA | 2007/3/23 | 2025/7/14 | high |
| 182188 | Control iD iDSecure Hard-coded JWT Key Authentication Bypass (CVE-2023-33371) | Nessus | SCADA | 2023/9/29 | 2026/3/23 | critical |
| 200986 | Rockwell Automation ThinManager ThinServer Improper Input Validation (CVE-2024-5990) | Nessus | SCADA | 2024/6/25 | 2024/10/23 | high |